
9
VERTICAL (with remote control unit)
The remote control gives you the possibility to control the flap in
two way:
1. Push the button to start the flap sweep. If you push
again the flap stops immediately.
2. Push the button to move the flap step by step.
HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.
ADJUSTING THE AIR FLOW DIRECTION
Set vertical vanes to the front position during COOLING/DRY
operation if humidity is high.
If the vertical vanes are set to the left-most or right-most
position, condensation will form around the air outlet and
drip off.
Do not move the flap with your hands when the air conditioner
is running.
EG
CAUTION
CAUTION
Left
Vertical vane
Right
2. WHEN THE AIR CONDITIONER IS RUNNING
If you want to turn off the air conditioner push the button with a
pen until the OPERATION lamp is turned off.
Power failure during operation.
In the event of power failure, the unit will stop. When the power
is resumed, the unit will restart automatically after 3 minutes.
NOTE
NOTES
If you have lost the remote control unit or it has troubles, follow
the steps below.
1. WHEN THE AIR CONDITIONER IS STOPPED
If you want to turn on the air conditioner push the button with a
pen to select the desired mode (COOL or HEAT).
OPERATION WITHOUT THE REMOTE
CONTROL UNIT
The air conditioner will start in automatic fan speed and flap
sweep operation. The temperature setting is 22°C for cooling
mode and 26°C for heating mode.
NOTE
Sweep function
The flap starts moving up and down to deliver air
over the sweep range.
• The flap automatically closes when the unit is off.
• During the heating operation, the fan speed
will be very low and the flap will be in the
horizontal position (position 6 ) until the air
being blown out of the unit begins to warm.
Once the air warms up, the flap position and
fan speed change to the settings specified
with the remote control.
• Use the FLAP button on the remote control to adjust
the position of the flap. If you move the flap by hand,
the factual flap position and the flap position on the
remote control may no longer match. If this should
happen, shut off the unit, wait for the flap to close,
and then turn on the unit again; the flap position will
now be normal again.
• Do not have the flap pointed down during cooling
operation. Condensation may begin to form around the
air vent and drip down.
CAUTION
Up
Down
Flap
Air outlet
grille
Operation
selector