COOLING ONLY MODELS
OPERATING LIMITS
L
Maximum conditions
Outdoor temperature :
43°C D.B.
Room temperature
:
32°C D.B. / 23°C W.B.
L
Minimum conditions
Outdoor temperature :
19°C D.B.*
Room temperature
:
19°C D.B. / 14°C W.B.
L
Model name GRVxxxL
* : –15°C D.B.
HEAT PUMP MODELS
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature :
43°C D.B.
Room temperature
:
32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature :
19°C D.B.
Room temperature
:
19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature :
24°C D.B. / 18°C W.B.
Room temperature
:
27°C D.B.
L
Heating Minimum conditions
Outdoor temperature :
–8°C D.B. / –9°C W.B.
EG
I
F
D
E
INSTALLATION INSTRUCTIONS
- Compact wall-mounted split units
CSMC(V)72/92/122 C/L/R -
Power Supply:
220 - 240 V ~ 50 Hz
*
Available only for heat pump models.
DRAIN
1
ELBOW
*
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
RAWL PLUG
6
TAPPING
6
SCREW
REMOTE
1
CONTROL UNIT
AAA ALKALINE
2
BATTERY
AIR CLEAN
2
FILTER
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
1
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
Tools required for installation (not supplied)
Model Combinations
Combine indoor and outdoor units only as listed below.
HEAT PUMP MODELS R22
Indoor Units
Outdoor Units
MCA72R5TA-
GR72R5TA-
MCA92R5TA-
GR92R5TA-
MCA122R5TA-
GR122R5TA-
COOLING ONLY MODELS R407C
Indoor Units
Outdoor Units
MCAV72C5TA-
GRV72C5TA-
GRV72L5TA-
MCAV92C5TA-
GRV92C5TA-
GRV92L5TA-
MCAV122C5TA-
GRV122C5TA-
GRV122L5TA-
HEAT PUMP MODELS R407C
Indoor Units
Outdoor Units
MCAV72R5TA-
GRV72R5TA-
MCAV92R5TA-
GRV92R5TA-
MCAV122R5TA-
GRV122R5TA-
R407C MODELS: for the other installation works of GRV models refer
to the “Installation Instructions” (green pages) on the top of the outdoor
unit.