background image

1. SPECIFICATIONS

1-1 Unit Specifications

DSAV92C5TAA

Power source

Voltage rating

Performance

Capacity
Air circulation (High/Med./Low)

m³/h

External static pressure (High)

Pa (mm W.G.)

Features

Controls/Temperature controls
Control unit
Timer
Fan speed

Air Filter
Operation sound (*)

High/Med./Low

dB-A

Refrigerant tubing connections
Refrigerant

Narrow tube

mm(in.)

tube diameter

Wide tube

mm(in.)

Refrigerant

Dimensions & Weight

Dimensions                           Unit

Height

mm

Width

mm

Depth

mm

Package dimensions            Unit

Height

mm

Width

mm

Depth

mm

Volume

m3

Weight                                 Unit

Net

kg

Shipping

kg

DATA SUBJECT TO CHANGE WITHOUT NOTICE

(*) Power level measured at operating conditions (HIGH speed / 5mmH20 external static pressure) and inside
      discharge air duct

266
571
852
365

Cooling

220 - 240V ~  50Hz

230V

1086

0,3

30
34

6,35 (1/4)

745

3 and Auto /1(Hi)

9,52 (3/8)

See catalogue with the requested matching

600/510/440

49(5) at shipment - 69 (7) with booster cable

Microprocessor/ I.C. thermostat 

Wireless remote control unit 

ON/OFF 24 hours & Daily program, 1-hour OFF

R407C

Flare type

Washable

54/52/49

4

Summary of Contents for 387106945

Page 1: ...TECHNICAL DATA SERVICE MANUAL INDOOR UNIT DSAV92C5TAA DSAV122C5TAA SPLIT SYSTEM AIR CONDITIONER DSAV122C5TAA 387106946 0 8180 310 1 12 2003 Model No Product Code No DSAV92C5TAA 387106945...

Page 2: ...w wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line...

Page 3: ...3 4 4 Drain Pump and Float Switch 14 5 TROUBLESHOOTING 15 5 1 Check before and after troubleshooting 15 5 2 Air conditioner does not operate 15 5 3 Some part of air conditioner does not operate 19 5 4...

Page 4: ...ions Unit Height mm Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Weight Unit Net kg Shipping kg DATA SUBJECT TO CHANGE WITHOUT NOTICE Power level measured at operati...

Page 5: ...Width mm Depth mm Package dimensions Unit Height mm Width mm Depth mm Volume m3 Weight Unit Net kg Shipping kg DATA SUBJECT TO CHANGE WITHOUT NOTICE Power level measured at operating conditions HIGH s...

Page 6: ...BLK GRY 15 GRY VLT 15 WLT RED 30 RED YEL 101 Safety devices Type Operating temp Open C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE Fan...

Page 7: ...T 15 WLT RED 30 RED YEL 101 Safety devices Type Operating temp Open C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm face area m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE Fan speeds H M L meas...

Page 8: ...sor TH1 Resistance Thermistor Room sensor TH2 Resistance Drain pump Model Rating Voltage Input Total head capacity Safety float switch Model Contact rating BI 1300 2725 230V AC DC 0 5A PC 309564003 22...

Page 9: ...I 9...

Page 10: ...2 DIMENSIONAL DATA Units mm 10...

Page 11: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams 11...

Page 12: ...trol circuit has a built in automatic time delay to allow the internal pressure to equalize As a protective measure the control circuit switches the compressor OFF not before than 5 minutes of compres...

Page 13: ...oor fan Continuous operation L low speed LL very low speed intermittent ventilation only while the compressor is ON Dry B zone Compressor FMI indoor fan Intermittent operation ON for 3 minutes and OFF...

Page 14: ...rain Pump OFF Float Switch NOTE Either in Heating or another mode or the unit is stopped when the float switch is turned ON the drain pump operates for 20 minutes minimum OFF OFF OFF OFF OFF OFF ON ON...

Page 15: ...nect power or turn off circuit breaker before you start checking or servicing 5 2 Air conditioner does not operate 5 2 1 Circuit breaker trips or fuse blows A When the circuit breaker is set to ON it...

Page 16: ...t in ON position Set OPERATION selector switch to ON Indoor PCB Ass y is defective NO Check power supply Power is being supplied to the indoor unit Circuit breaker is tripped Power failure Reset break...

Page 17: ...sure resistance of primary and secondary winding of transformer TR Indoor PCB Ass y is defective OK Measure resistance of indoor and outdoor fan motor winding FM Measure resistance of compressor motor...

Page 18: ...unit does not run Indoor PCB Ass y is defective OK NO Is room temperature too low Try to lower setting temperature by temperature setting button button Outdoor unit still does not run Remote control...

Page 19: ...tter in bearings Remove foreign matter or repair Repair or replace Measure resistance of outdoor fan motor winding Check fan motor capacitor Measure resistance of flap motor winding Fan cannot be turn...

Page 20: ...otor winding is abnormally high Refrigerant gas shortage Charge refrigerant gas Measure power supply voltage Rotor may be locked up The voltage is too low 5 3 4 Compressor and outdoor fan do not run F...

Page 21: ...ion of remote control unit Cool air from air conditioner reaches position directly Change position of remote control unit Wide and narrow tubes between indoor unit and outdoor unit are insulated Insul...

Page 22: ...will blink when either indoor coil thermistor or room air thermistor is defective At the same time the outdoor unit will stop Indoor unit will operate only for ventilation NOTE Operation lamp on fron...

Page 23: ...sure the resistance by placing a probe on each terminal screw on the terminal plate Fig 2 Note that the ground line terminal should be skipped for the check 6 1 4 Measurement of Insulation Resistance...

Page 24: ...n place a probe on the capacitor terminals as shown in Fig 7 Observe the deflection of the pointer setting the resistance measuring range of the multimeter to the maximum value The capacitor is good i...

Page 25: ...s on the PCB of each indoor unit with the switch positions of its remote control unit To change address on PCB 1 Set the switch n 2 to off position on the address dip switch S01 see detail on figure T...

Page 26: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Reviews: