background image

 
In Auto Mode the programs are called up automatically in a continuous loop. 
Press the MODE button to select the AUTO Mode. Press the ENTER button to select the 
desired frequency of the loops. The desired frequency of the loops (Frequency = FQN 
01-99) can be selected using the UP/DOWN buttons. Please press the ENTER button to 
confirm and to exit the AUTO Mode. 

 

 

Slave Operation 

 
The master/slave operation enables that several LED bars can be synchronized and 
controlled by one master device. For slave operation to function, XLR data cables must 
be used to connect fixtures together. To set this mode, press the MODE button to select 
the SLAVE mode. Any devices set in this manner can now be controlled by the master 
unit. Press the ENTER button to confirm and to exit the SLAVE Mode. 

 

 

Sound Active Operation  

 
Press MODE button until you reach the SOUND controlling mode, then the fixture will 
respond to the sound of audio. Press UP/DOWN to adjust the sound sensitivity levels 
(SENS00-31) & frequency (FQN01-99) of loops. Press the ENTER button to select the 
desired sensitivity and frequency of the loops, respectively. Press the ENTER button 
again to confirm and to exit the SOUND Mode. 

 

 

DMX Operation  

 
The DMX operation mode allows you to control the bar using a standard DMX controller. 
In this mode you set the start address at which the fixture will respond to the controller 
on.  Also the channel assignment mode to be used is set here.  To address simply press 
the MODE button until the display shows DMX MODE. Press the ENTER button and the 
display shows: 001. Set the desired address using the UP/DOWN buttons. Please press 
the ENTER button again to confirm and to select a DMX Channel Mode. After having set 
the desired address and pressed ENTER, you can now choose a DMX Channel Mode 
from 6, 9, 15, 24, and 27. Set the desired mode using the UP/DOWN buttons. Press the 
ENTER button again to confirm and to exit the DMX Mode. 
 

Note:

 The following DMX-512 Control section explains how to select a DMX start 

address for your fixture. It also covers connecting data cables, proper termination, 
specific channel assignments and channel value tables. 

 
 
 
 
 

DMX-512 Control

 

 

8

Summary of Contents for UltraLED Series DL-BAR10TC24

Page 1: ...Information specifically for DL BAR10TC24 v1 0 This manual contains important information Please read before operating fixture...

Page 2: ...o and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...P14 7 Auto Run Operation 7 Slave Operation 8 Sound Active Operation 8 DMX Operation 8 DMX 512 Control 8 DMX Data Connection 9 Data Terminator 9 Adapter 5 to 3 pin 9 DMX Start Address 10 DMX Channel A...

Page 4: ...x 5 9 x 6 3 Weight 13 2 lbs 6 0 kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated su...

Page 5: ...on of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in...

Page 6: ...des that are available on this fixture via the LCD Control Panel display All functions are selectable from the display menu located at the back of the fixture Control Panel Menu Operation Settings Use...

Page 7: ...n color dreaming Speed Strobe adjustable P3 METEOR Speed 00 99 Strobe 00 99 Seven color flow Speed Strobe adjustable P4 FADE Speed 00 99 Strobe 00 99 Seven color fade Speed Strobe adjustable P5 CHANGE...

Page 8: ...NS00 31 frequency FQN01 99 of loops Press the ENTER button to select the desired sensitivity and frequency of the loops respectively Press the ENTER button again to confirm and to exit the SOUND Mode...

Page 9: ...ain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no bra...

Page 10: ...irst possible Start Address 1 This fixture occupies DMX channels 1 thru 6 The next DMX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requ...

Page 11: ...6 channel mode fully describes the function of channel 1 Reference this table for all other DMX channel modes Macro CH 1 will over ride all other channels in all modes CH 1 CH 2 CH3 CH4 CH5 CH6 Macro...

Page 12: ...15 11 21 Master Dimmer 0 255 Strobe 0 255 R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 24 Channel Mode CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 R1 G1 B1 R2 G2 B2 R3 G3...

Page 13: ...reme care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect cl...

Page 14: ...after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmi...

Reviews: