background image

 

10 

DMX-OUT

XLR Connector - Socket:



3
4
5

 
 
 

- Ground
- Signal (-)
-
-
-

 
 
 

S

(Unused)

ignal 

 
 

(+)

1

2

3

4

5

 

DMX-IN



3
4
5

 
 
 

- Ground
- Signal (-)
-
-
-

 
 
 

S

(Unused)

ignal 

 
 

(+)

XLR Connector - Plug:

1

2

3

4

5

DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for  the  fixture  (see  DMX  Background).    Before  addressing  fixtures,  consult  the  manual  of  the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from  1  to  512.    Fixtures  requiring  more  than  one  channel  for  control  will  read  subsequent 
channels up to the total number of channels required.  Since this fixture requires a maximum of 
10 channels of DMX, if set to a Start Address of 11 it would use data from channels: 11, 12, 13, 
14,  15,  16,  17,  18,  19,  and  20.  Choose  a  Start  Address  so  the  channels  used  do  not  overlap 
with other fixtures.  In some cases, it may be desirable to set two or more same type fixtures to 
the  same  Start  Address.    In  this  case,  the  fixtures  will  be  slaved  together  and  respond  to  the 
same data.  Because all fixtures see the same data, fixtures may be set to any address without 
concern for the order they are connected by the DMX cables.   
 
 
 
 

DMX Data Connection 

This  fixture  uses  XLR  type  connectors.    Use  shielded  twisted  pair  cable  approved  for 
EIA-422/EIA485 use.  Fixtures are connected in Daisy Chain topography:  Connection is 
made from the controller to the DMX-IN of the first light, then from the DMX-OUT to the 
DMX-IN  of  the  next  light  and  so  on.    Only  one  data  source  can  be  on  a  chain  and  no 
branching  is  allowed.    The  physical  order  in  which  the  fixtures  are  connected  is  not 
important, use the most convenient.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Data Terminator 

A  Data  Terminator  can  be  purchased  to  connect  to  the  DMX-OUT  of  the  last  fixture  to 
reduce  the  effects  of  signal  noise.  To  make  a  Terminator,  connect  a  120-ohm  ¼  watt 
resistor  across  pin  2,  Data  Negative  (S-)  and  pin  3,  Data  positive  (S+).  A  qualified 
technician can determine if a Data Terminator is required. 

 
 
 

DMX-OUT

1

- Ground

- Signal (-)
- Signal (+)

XLR Connector - Socket:

 

DMX-IN



- Ground
- Signal (-)
- Signal (+)

XLR Connector - Plug:

Summary of Contents for TH-SCLPM20QA/B

Page 1: ...SCULPT 20 LED Profile Mini LED Ellipsoidal Information specifically for TH SCLPM20WW B TH SCLPM20QW B TH SCLPM20QA B V2 0 This manual contains important information Please read before operating fixtur...

Page 2: ...not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux...

Page 3: ...ons 9 TH SCLPM20WW Menu Settings 9 TH SCLPM20QW or QA Menu Settings 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapters for 3 or 5 pin XLR 11 DMX Start Address 11 DMX Channel Assig...

Page 4: ...e 5 to 113 F 20 to 45 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Voltage 12v DC Rated Power 22W Connection DC coaxial connector Rating...

Page 5: ...ts received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and to assure peak performance of said...

Page 6: ...rientation provided appropriate clamp is used to mount securely Secure all cables properly and keep away from hot surfaces to prevent heat damage and trip hazards Do not obstruct any vents 1 LED Displ...

Page 7: ...hoose the orientation that puts the Color Frame Locking Clip is in the most up position to prevent color frames from accidentally falling when unlocked 3 Reinstall Focus Knobs adjust lens back and for...

Page 8: ...ring Diagrams There are two basic ways to use the fixture One is in standalone which does not require the use of any data lines to be connected nor any controller each fixture would operate independen...

Page 9: ...o Scenes two demo looks to choose from when no DMX control Master mAst On off Master Mode default is Off When On unit outputs the current settings MENU Display Options Description Address A001 r001 51...

Page 10: ...ress In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address without concern for the order they are con...

Page 11: ...ddresses Example Select Start Addresses for 4 fixtures each requiring 2 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX c...

Page 12: ...ect 4 Macro Speed 000 255 Rainbow speed 5 Red 000 255 Red Intensity Level 0 100 6 Green 000 255 Green Intensity Level 0 100 7 Blue 000 255 Blue Intensity Level 0 100 8 White 000 255 White Intensity Le...

Page 13: ...to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and...

Page 14: ...rent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receivin...

Page 15: ...Block Adaptor CA XLR5 5 5 DMX 5 pin XLR Cable CA XLR5 10 10 DMX 5 pin XLR Cable CA XLR5 15 15 DMX 5 pin XLR Cable CA XLR5 25 25 DMX 5 pin XLR Cable CO XLRTERM3 XLR 3 Pin Data Terminator CO XLRTERM5 XL...

Page 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Reviews: