background image

 8

fixtures will be slaved together and respond to the same data.  Because all fixtures see the 
same data, fixtures may be set to any address without concern for the order they are connected 
by the DMX cables.   

 
Note:

 For DMX to operate on this unit it must be set to SLAVE mode.  

 

DMX Data Connection 

This fixture uses 5 pin XLR type connectors and shielded twisted pair cable approved for 
EIA-422/EIA485 use.  Fixtures are connected in Daisy Chain topography:  Connection is 
made from the controller to the DMX-IN of the first light, then from the DMX-OUT to the 
DMX-IN of the next light and so on.  Only one data source can be on a chain and no 
branching is allowed.  The physical order in which the fixtures are connected is not 
important, use the most convenient.  

 
 
 
 
 
 
 

 

 

Data Terminator 

A Data Terminator can be connected to the DMX-OUT of the 
last fixture to reduce the effects of signal noise; it is not required 
for all installations. To make a Terminator, connect a 120-ohm 
¼ watt resistor across pin 2, Data Negative (S-) and pin 3, Data 
positive (S+). Whether it is a 5 pin XLR or 3 pin XLR connector 
(shown on right) does not matter, the pin numbers remain the 
same. A qualified technician can determine if a Data Terminator 
is needed. 

 

Adapter

 

5-to-3 pin 

Systems using 5 pin DMX interfaces can be accommodated by purchasing 3-to-5 pin 
adapters or building adapter cables.  Numbers designating each pin can be found on 
connectors.  Converting between the two XLR types is done in a pin-to-pin fashion.   
Connect the shields to pin 1, then connect pin 2 to pin 2 and pin 3 to pin 3, regardless of 
either connector’s gender or pin count.  No connection is made to Pins 4 & 5. 
 

 
 

 

5 Pin XLR (Plug)
Pin 1: GND(Sheild)

Pin 2: Signal(-)

Pin 3: )

Pin 4: N/C

Pin 5: N/C

3 XLR 

(S

)

Pin 1: GND(Sheild)

Pin 2: Signal(-)
Pin 3: )

Pin ocket

5 Pin XLR (Socket)

Pin 1: GND(Sheild)
Pin 2: Signal(-)

Pin 3: )

Pin 4: N/C

Pin 5: N/C

3  

XLR 

(Plug)

Pin 1: GND(Sheild)

Pin 2: Signal(-)
Pin 3: )

Pin

 

DMX-IN



3
4

5

 
 

 

- Ground
- Signal (-)
-
-

-

 
 

 

S

(Unused)

ignal 

 

(+)

XLR Connector - Plug:

1

2

3

4

5

DMX-OUT

XLR Connector - Socket:



3
4
5

 
 

- Ground
- Signal (-)
-
-
-

 
 

S

(Unused)

ignal 

 
 

(+)

1

2

3

4

5

Summary of Contents for FlexiLED Series

Page 1: ...Information specifically for DL FLEXILED100TC B V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...d to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer...

Page 3: ...7 DMX Data Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 3 Channel Mode 03 9 5 Channel Mode 05 9 Channel Values and Functions 5 Channel Mode 10 CH 1...

Page 4: ...unting hole Physical Color Black Size 12 W x 8 75 H x 13 L Weight 9 5 lbs 4 32 kgs Housing Material Aluminum Environmental Location Indoor Min distance to flammable surface 3 3ft 1m Min distance to il...

Page 5: ...of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Page 6: ...utput beam of the fixture By using certain light diffusers it is possible to create different desired lighting effects A desired effect might be a softer or diffused light beam Many diffraction materi...

Page 7: ...dressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixt...

Page 8: ...inator connect a 120 ohm watt resistor across pin 2 Data Negative S and pin 3 Data positive S Whether it is a 5 pin XLR or 3 pin XLR connector shown on right does not matter the pin numbers remain the...

Page 9: ...e previous fixture s Start Address to its channel requirement 1 5 6 To maximize channel usage we will leave no empty channels between fixtures so the second Start Address is set to DMX channel 6 and t...

Page 10: ...ls the actual output level while the relative level of each color is set by the R G or B channels CH 5 Effect The effect DMX channel selects between normal sound activation or strobe flashing operatio...

Page 11: ...or effects 3 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 4 Inspect clamps and safety cables to ensure fixture is secu...

Page 12: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Reviews: