background image

 

10 

CH 3   : Green 

Sets relative intensity of Green. 
 Actual value is subject to 
Master Dimmer channels.  The 
Color Macro/Scroll Channel will 
override this channel. 

 
 

CH 4   : Blue 

Sets relative intensity of Blue.  
Actual value is subject to Master 
Dimmer channels.  The Color 
Macro/Scroll Channel will 
override this channel.   

 
 

CH 5   : Color Macro/Scroll 

The Color Macro/Scroll selects between 16 colors and two Color Scroll Modes.  The first 
Color Scroll Mode snaps between colors, the second Color Scroll Mode fades between 
colors. This will override the relative values set by the individual RGB channels 2, 3 & 4. 

 

CH 5 – Color Macro/Scroll 

DMX Value 

Function 

0-4 

No Macro or Scroll 

5-9 

Cool White 

10-14 

Lt. Blue 

15-19 

Blue 

20-24 

Purple 

25-29 

Blue Magenta 

30-34 

Magenta 

35-39 

Hot Pink 

40-44 

Pink 

45-49 

Red 

50-54 

Orange 

55-59 

Yellow 

60-64 

Lime 

65-69 

Lt. Green 

70-74 

Green 

75-79 

Teal 

80-84 

Cyan 

85-89 

Color Scroll Snap Speed 1 (Fastest) 

90-94 

Color Scroll Snap Speed 2 

95-99 

Color Scroll Snap Speed 3 

100-104 

Color Scroll Snap Speed 4 

105-109 

Color Scroll Snap Speed 5 

110-114 

Color Scroll Snap Speed 6 

115-119 

Color Scroll Snap Speed 7 

120-124 

Color Scroll Snap Speed 8 

125-129 

Color Scroll Snap Speed 9 

130-134 

Color Scroll Snap Speed 10 

135-139 

Color Scroll Snap Speed 11 

CH 3 – Green 

DMX Value 

Function 

0-4 

No Output 

5-255 

Intensity - Off to Full On 

CH 4 – Blue 

DMX Value 

Function 

0-4 

No Output 

5-255 

Intensity - Off to Full On 

Summary of Contents for DL-PAR64TC18/B

Page 1: ...Information specifically for DL PAR64TC18 B Black DL PAR64TC18 P Polished V1 This manual contains important information Please read before operating fixture...

Page 2: ...all not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni L...

Page 3: ...7 Mode 3 Color Fade 7 Mode 4 Sound Active 7 Mode 5 Slave 7 Mode 6 DMX 7 DMX 512 Control 8 DMX Data Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignment 9 CH...

Page 4: ...LED display menu for settings Dual yoke for floor or hang mounting Clamp mounting hole Physical Color Black or Polished Size 13 x 11 25 x 10 6 Weight 7 7 lbs 3 5 kg Housing Material Aluminum Environm...

Page 5: ...f the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packi...

Page 6: ...ifferent modes that are available on this fixture via the LED display Each mode is selectable from the display menu located at the back of the fixture Modes 1 to 5 refer to the stand alone operations...

Page 7: ...to the next and at different speeds F300 RGB fades through RGB at a speed set from 00 99 F700 7 COLOR fades through 7 standard colors at a speed from 00 99 FF00 STROBE sets the flashing speed from 00...

Page 8: ...he first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no branching is allowed The physical order in which the fixtures are connected...

Page 9: ...will leave no empty channels between fixtures so the second Start Address is set to DMX channel 7 and that fixture occupies channels 7 thru 12 The third fixture will be addressed 7 6 13 and occupy ch...

Page 10: ...or Macro Scroll DMX Value Function 0 4 No Macro or Scroll 5 9 Cool White 10 14 Lt Blue 15 19 Blue 20 24 Purple 25 29 Blue Magenta 30 34 Magenta 35 39 Hot Pink 40 44 Pink 45 49 Red 50 54 Orange 55 59 Y...

Page 11: ...oll FADE Speed 6 200 204 Color Scroll FADE Speed 7 205 209 Color Scroll FADE Speed 8 210 214 Color Scroll FADE Speed 9 215 219 Color Scroll FADE Speed 10 220 224 Color Scroll FADE Speed 11 225 229 Col...

Page 12: ...the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Or...

Page 13: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...

Reviews: