IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts 
for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 
Model Number (circle):  

DL-OCTOBAR830TC 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

 
 

Summary of Contents for DL-OBAR830TC

Page 1: ...Information specifically for DL OCTOBAR830TC v1 0 This manual contains important information Please read before operating fixture...

Page 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 Invert Function 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Ad...

Page 4: ...x 7 1 Weight 13 64 lbs 6 2 kgs Housing Material Aluminum and steel Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminat...

Page 5: ...urn Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to sh...

Page 6: ...ket may be used to floor stand this unit or mount on wall Mounting holes are provided on each bracket to help accommodate a clamp Always keep cords out of the way thus preventing any trip hazards Secu...

Page 7: ...fixture you can select one static color or from 13 different program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode S...

Page 8: ...the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN but...

Page 9: ...Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required In 5 channel mode the fixture...

Page 10: ...dress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wis...

Page 11: ...3 Ch 1 2 3 Ch 1 2 3 5 channels Bar completely operates as 1 complete section only with additional Master dimmer strobing and sound control channels Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2...

Page 12: ...CH 26 CH 27 R5 G5 B5 R6 G6 B6 R7 G7 B7 R8 G8 B8 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0 255 5 000 000 On No F...

Page 13: ...ster dimmer 72 79 Color 1 Master dimmer 80 87 Color 2 Master dimmer 88 95 Color 3 Master dimmer 96 103 Color 4 Master dimmer 104 111 Color 5 Master dimmer 112 119 Color 6 Master dimmer 120 127 Color 7...

Page 14: ...or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secur...

Page 15: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Reviews: