background image

 

 
 

 
 
 

 

 
 
 
 
 
 
 
 
 

Information specifically for:

 

 

 

DL-LEDPANEL36C/B – Black with RGB LEDS 

 DL-LEDPANEL36C/W 

– 

White 

with 

RGB 

LEDS 

      

DL-LEDPANEL36W/B – Black with White/Amber LEDS 
DL-LEDPANEL36W/W – White with White/Amber LEDS 
DL-LEDPANEL36UV/B – Black with UV LEDS 

V2.0 

This manual contains important information.

Please read before operating fixture.

Summary of Contents for DL-LEDPANEL36C/B

Page 1: ...RGB LEDS DL LEDPANEL36C W White with RGB LEDS DL LEDPANEL36W B Black with White Amber LEDS DL LEDPANEL36W W White with White Amber LEDS DL LEDPANEL36UV B Black with UV LEDS V2 0 This manual contains i...

Page 2: ...e price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an R...

Page 3: ...andalone Program 9 Setting Master Slave 9 P x y Standalone Program Chart RGB models only 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 11 DMX C...

Page 4: ...ient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 100 265vAC 50 60Hz Rated Power 40W Fuses Internal Ra...

Page 5: ...f the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Page 6: ...justable base which allows the panel to be tilted at different desired angles Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixtur...

Page 7: ...out cables This allows the units to receive data either from the master unit or the DMX controller Data wiring is explained in more detail in the DMX Data Connection section of this manual Example Bl...

Page 8: ...ew settings wait 10 seconds The three digit display is the DMX512 Start Address and the P x y display is the selected internal program Setting the Start Address for DMX512 Control 1 When a DMX signal...

Page 9: ...aster unit P x y Standalone Program Chart RGB models only X Program Y Option P0 Black out Brightness level of 0 no output P1 Static Red Brightness lowest 1 to brightest at 9 P2 Static Green Brightness...

Page 10: ...le approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the n...

Page 11: ...tween fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture i...

Page 12: ...ity of Green CH 3 Blue Sets relative intensity of Blue Channel Function 1 UV set 1 0 255 2 UV set 2 0 255 3 UV set 3 0 255 CH 1 Red DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 G...

Page 13: ...UV LEDS in set 2 CH 3 UV Sets relative intensity of UV LEDS in set 3 CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 White DMX Value Function 0 No Output 1 255 Intensity...

Page 14: ...e a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description C...

Page 15: ...is sent all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to ide...

Page 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...