Control Panel Menu 

Use the fixture’s Control Panel to access the Control Menu.  The MODE Key puts the 
fixture in the settings menu itself and also acts as a BACK key between options, 
UP/DOWN moves through the menu options and allows the assignment of a value. The 
ENTER key is used to enter that option and confirms the selection once the UP/DOWN 
is used to adjust the value. When in edit, the display will Flash. Settings are stored and 
recalled on subsequent power cycles. R, G, B, W refers to Red, Green, Blue and White 
respectively. DMX and master/slave modes require data cables to be connected between 
fixtures. Manual and some stand-alone modes do not require data cables for 
independent use of the fixture.  The display will shut off after 30 seconds, press any 
button to relight it.  

 

 
Note:

  The factory default CHANNEL MODE is set to “07” the 7 channel DMX mode. 

 

 

DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for the fixture (see DMX Background).  Before addressing fixtures, consult the manual of the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from 1 to 512.  Fixtures requiring more than one channel for control will read subsequent 
channels up to the total number of channels required.  Since this fixture requires a maximum of 
7 channels of DMX, if set to a Start Address of 8 it would use data from channels: 8, 9, 10, 11, 
12, 13 and 14.   Choose a Start Address so the channels used do not overlap with other 
fixtures.  In some cases, it may be desirable to set two or more same type fixtures to the same 
Start Address.  In this case, the fixtures will be slaved together and respond to the same data.  
Because all fixtures see the same data, fixtures may be set to any address without concern for 
the order they are connected by the DMX cables.   

Menu Options 

Function 

Options 

DMX MODE 

 

 

ADDR 

Select DMX Start Address 

001-512 

CHANNEL 

Select Number of DMX Operating Channels 

CH:

 04 = 4 ch, 06 = 6 ch or 07 = 7 channels 

STATIC 

Allows a static scene to be set 

R00G00B00W00  F00 

set R 0-255, G 0-255, B 0-255, W 0-255 
F Flash speed from 00 to 99 
 

CHANGE-15 

15 Color change scroll 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

CHANGE-4 

4 Color change scroll 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

DREAM 
 

15 Color fading 
 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

MASTER/ 
SLAVE MODE 

Selects master or slave mode 

MASTER

: master fixture 

SLAVE

: slave fixture 

Summary of Contents for DL-LEDIF98QO

Page 1: ...Information specifically for DL LEDIF98QO V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...ited to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the deal...

Page 3: ...ddress 9 DMX Channel Assignments 9 4 Channel Mode 9 6 Channel Mode 10 7 Channel Mode 10 Channel Values and Functions 7 Channel Mode 10 CH 1 Master Dimmer 10 CH 2 Strobe 10 CH 3 Red 11 CH 4 Green 11 CH...

Page 4: ...Housing Material Aluminum casting and Stainless steel hardware Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to...

Page 5: ...scription of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products recei...

Page 6: ...D Display Menu Setting Buttons Setup and Operation Modes LCD Display The following refers to the different modes that are available on this fixture via the LCD Control Panel display All functions are...

Page 7: ...xtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires a maximum of 7 channels of DMX if set to a Star...

Page 8: ...watt resistor across pin 2 Data Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be ac...

Page 9: ...hru 7 The next DMX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 7 8 To maximize channel usage we will leave no empty chann...

Page 10: ...present value Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 White 0 255 5 Master Dimmer 0 255 6 000 000 On No Function 001 005 Off No output 006 010 On 011 255 Strobe slow to fast Channel...

Page 11: ...Color Macro Scroll The Color Macro Scroll scrolls between 15 colors either by snapping from one color to the next or by fading This will override the relative values set by the individual RGBW channe...

Page 12: ...adjust via to select the 3 scenes FL Flash on off adjust speed via SP Speed control via to adjust the color change speed and dream fade speed D DMX mode SA Not in use SL Master slave mode S Setting DM...

Page 13: ...ical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items...

Page 14: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Reviews: