background image

 

13

Maintenance 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a vacuum with a soft brush to remove dust collected on external vents and internal 
components.  If using an air compressor, use low pressures and extreme care to prevent 
damaging any internal parts or effects. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and cleaner safe for plastics.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 
 
 

Accessory Items 

(sold separately)

 

 

Order Code 

Description 

CLAMP-MEGA/BSS 

Mega Heavy Duty Aluminum Clamp w/Stainless – Black 

CLAMP-CBHALF 

Half Cheeseborough Coupler 300kg Max Load  

 

 

SAFETYCABLE18B 

Safety Cable Black 18” 

SAFETYCABLE18S 

Safety Cable Silver 18” 

 

 

 

 

ZEPO0005 

Extension IP Link Jumper Power Cable - 6' with male to 
female connectors – Black 

ZEPO0006 

Extension IP Link Jumper Data Cable - 6' with male to 
female connectors – Black 

 

 

CA-XLR3/5 

Pre-made 5’  3-pin XLR Cable 

CA-XLR3/10 

Pre-made 10’ 3-pin XLR Cable 

CA-XLR3/25 

Pre-made 25’ 3-pin XLR Cable 

CA-XLR3/50 

Pre-made 50’ 3-pin XLR Cable 

CA-XLR3/100 

Pre-made 100’ 3-pin XLR Cable 

 

 

CO-XLR3M   

XLR Connector 3-pin Male 

CO-XLR3F 

XLR Connector 3-pin Female 

 

 

CO-XLRTERM3 

XLR 3 Pin Data Terminator 

 

 

CO-XLR3MTO5F 

XLR 3 Pin Male to 5 Pin Female Adapter 

CO-XLR5MTO3F 

XLR 5 Pin Male to 3 Pin Female Adapter 

 

Summary of Contents for DL-LEDIF150TCO

Page 1: ...Information specifically for DL LEDIF150TCO V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...ted to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the deale...

Page 3: ...Start Address 9 DMX Channel Assignments 9 3 Channel Mode 9 5 Channel Mode 10 6 Channel Mode 10 Channel Values and Functions 6 Channel Mode 10 CH 1 Master Dimmer 10 CH 2 Strobe 10 CH 3 Red 11 CH 4 Gree...

Page 4: ...5 lbs 8 7 kgs Housing Material Aluminum casting and Stainless steel hardware Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Mi...

Page 5: ...scription of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products recei...

Page 6: ...and out Barndoors can be used to control the light beam reduce glare and light spill The barndoor can also be used to block light off of surfaces where light may not be desired The following refers to...

Page 7: ...12 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires a maximum of 6 channels of DMX if set to a...

Page 8: ...watt resistor across pin 2 Data Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be ac...

Page 9: ...els 1 thru 6 The next DMX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 6 7 To maximize channel usage we will leave no empt...

Page 10: ...een Off and its present value Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0 255 5 000 000 On No Function 001 005 Off No output 006 010 On 011 255 Strobe slow to fast Channe...

Page 11: ...croll The Color Macro Scroll scrolls between 7 colors either by snapping from one color to the next or by fading This will override the relative values set by the individual RGB channels 3 4 5 CH 6 Co...

Page 12: ...ams adjust via to select the 3 scenes FL Flash on off adjust speed via SP Speed control via to adjust the color change speed and dream fade speed D DMX mode SA Not in use SL Master slave mode S Settin...

Page 13: ...ical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items...

Page 14: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Reviews: