background image

 

 

 

 

                                                                                              2 

3.

 

Never touch new lamps with your fingers: use a tissue or a cloth. 

 

In order to  replace the lamp, disconnect from main power supply first, and unscrew the lamp replacement cover. Only 

use the appropriately rated lamps as use of any other lamp type many cause the unit to be non-operational. 

Due to the nature of the mercury vapor discharge lamp it is vitally important that you do not touch the new replacement 

lamp with your bare fingers, as this will reduce lamp life considerably. Once again a clean tissue or cloth can be used for 

fitting the replacement lamp. After replacement of the lamp, if the unit is still not working then please contact your local 

dealer or our company for assistance.          

CLEANING 

The most important part of maintaining lighting fixture is to keep it clean.  By keeping the reflector clean, it will allow 

more light to be transmitted & projected forward, thus producing a better UV effect and cooler operation. This should be 

cleaned with a soft damp cloth. The body of the unit may also be cleaned in the same way. Make sure all vents are free 

of debris and ventilation obstructed in any way. Any internal cleaning should be performed  by a fully qualified 

technician.   

MAINTENANCE & SERVICING   

Any work on internal parts should be carried out by a qualified technician only. Removal of covers other than the front 

to replace lamp is considered a breach of warranty and will not be covered under any such agreement unless authorized 

first by our company. 

TROUBLESHOOTING 

 

If the unit is not functional-check main power supply is ‘on’ and at the correct voltage. 

 

If the unit is functional but lamp does not light, lamp may require replacing. 

 

If the unit lights up but it not very bright, lamp maybe very old and requires replacement or unit is not receiving 

proper voltages. Make sure unit is not plugged into any dimming device. 

POWER CONNECTIONS 

The unit is supplied with an Edison power plug appropriate to its voltage. Should any other connections be required they 

must be carried out with the following configuration. 

Earth = Green/Yellow cable 

Common/Neutral = Blue cable 

Hot/Live = Brown cable 

In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection. 

In the UK, it is required that all mains plugs are fitted with 5A fuses. 

TECHNICAL SPECIFICATIONS 

Power: 

 

120V~60Hz AC   

Fuse: 

 

5A/125V 

Lamp: 

 

LH125BL-T 125W(E27) 

Dimensions:  216x254x254mm 

Weight:   

7.7KG 

Warranty:  

Limited 90-day warranty 

Reviews: