Technaxx TX-214 User Manual Download Page 15

15 

Model: TX-214,TX-215; Article No. 5023,5024; 10/2022 

Technical specifications 

Modell 

TX-214 

TX-215 

Solar Panel 

Max. power (Pmax) 

50W 

100W (2x50W) 

Max. voltage (Vmp) 

18V 

Max. current (Imp) 

2.78A 

5.56A 

Open circuit voltage (Voc) 

21.78V 

Short circuit current (Isc) 

2.95A 

5.89A 

Operating temperature 

-40°C ~ 

+85°C 

Output power tolerance 

±5% 

Module Efficiency 

16.69% 

Maximum System Voltage 

500Vdc 

NMOT 

46°C±2°C 

Temperature Co-efficient of Pmax 

-0.39%/°C 

Temperature Co-efficient of Voc 

-0.30%/°C 

Temperature Co-efficient of Isc 

0.06%/°C 

Front Cover 

3.2mm tempered glass 

Junction Box 

IP65 rated 

 

Charge controller

 

System voltage 

12V 

Battery operating voltage range 

8-32V 

Rated current 

Charge 

10A 

Load 

10A 

Maximum PV input voltage 

50V, enable protection and stop charging. 

Below 45V, charge resumes 

Charging mode 

The default is PWM charging, b04/b07 can be 

set to intermittent charging 

USB output 

5V/2A 

Static power consumption 

≤10mA 

Operating temperature 

-35 ~ +60°C 

Altitude 

3000m 

IP rating 

IP32 

Product size 

120x75x34mm 

Installation size 

108.5x58.5mm 

Weight 

130g 

 

General 

Cable connection 

MC4 / terminals 

Cable length (total) 

3m 

Weight (total) 

4.1kg 

8.2kg 

Dimensions (total) 

57x53.5x4.0cm 

57x 53.5x6.6cm (folded); 

107x 57x4.0cm (unfolded) 

Summary of Contents for TX-214

Page 1: ...unless they are supervised or instructed on the use of this device by a person responsible for their safety Children should be supervised to ensure they do not play with this device Keep this user ma...

Page 2: ...9 System voltage type selection interface 9 Battery type settings 9 Load operating mode adjustment interface 9 Display current controller temperature 10 Display the charge current 10 Display the load...

Page 3: ...e power cord do not pull it over sharp edges or hot surfaces do not use the power cord for carrying If the power cord of this device is damaged it must be replaced The appliance is intended for househ...

Page 4: ...bility of secondary damage e g falling off the roof must be taken into account in the event of electric shocks Never touch the positive and negative terminals at the same time or short circuit them Ca...

Page 5: ...arry island solution TX 215 Ideal for garden camping etc and charges e g car or camper battery Excellent for charging DC12V utility batteries Suitable for lead acid and lithium batteries Charge contro...

Page 6: ...user manual Prduct overview 50W Solar Charger Set TX 214 1 Hinged adjustable stand 5 Charge controller 2 Solar panel 6 MC4 connector extension cable 3 Junction box 7 Terminals for power storage 4 DC1...

Page 7: ...a fraction of the nominal rated power is achieved CAUTION If you use the solar panel on or in the car or in the car do not use it in traffic Solar panel TX 214 The solar panel is from factory connect...

Page 8: ...en running Install the controller on a flat well ventilated surface System Wiring 1 Connect the anode and cathode of the battery to the controller according to the diagram and take care to avoid rever...

Page 9: ...ashes Then press to adjust After adjustment press and hold for 2s again until the number no longer flashes At this point the setting is complete Battery type settings b01 Sealed lead acid battery defa...

Page 10: ...rrent Display the load current Boost charge voltage regulation interface only valid for b04 b07 When the battery voltage rises to this set voltage PWM charging is enabled During normal charging the ar...

Page 11: ...ll delay to turn on the load Such time value can be used to prevent turning off the lamp due to erroneous judgment caused by the interference of car lights or lightning at night Setting recommendation...

Page 12: ...03 FLD b04 Ternary lithium b07 Lithium iron phosphate High voltage protection HVD 16 0V 16 0V 16 0V 16 0V 16 0V High voltage recovery HVR 15 0V 15 0V 15 0V 15 0V 15 0V Boost charge voltage 14 4V 14 2V...

Page 13: ...e If short circuit protection is triggered at the load side the load will be turned off immediately After 10s the controller will automatically turn the load on again Load over current state When the...

Page 14: ...rol is set up but the load is not turned on during the day In this case battery is low resulting in the controller to cut off the load or the load is not properly connected disconnected burned out or...

Page 15: ...Isc 0 06 C Front Cover 3 2mm tempered glass Junction Box IP65 rated Charge controller System voltage 12V Battery operating voltage range 8 32V Rated current Charge 10A Load 10A Maximum PV input voltag...

Page 16: ...posal Dispose of cardboard and paperboard in the waste paper Foils should be submitted for recyclables collection Disposing of old equipment Applies in the European Union and other European countries...

Reviews: