Technalogix Ltd
.
VIII-8
POWER -
Tactile
button to turn carriers on and off. To turn off, must be depressed for
at least 2 seconds. Tied internally through DB9 connectors to all other
POWER buttons.
NAVIGATE -
Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
SELECT-
Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
RESET -
Tactile button to reset microcontroller in control board. Also clears existing
faults. Individual control board with reset comes back on with soft start feature.
RF IN –
RF input from modulator or processor. BNC connector, 50 ohm.
RF OUT –
100-watt RF output. Connects to inline wattmeter (not supplied) and antenna. N
connector, 50 ohm.
REMOTE PORT -
pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample (28Vdc nominal)
AC IN –
AC input to switching power supply. Switching power supply draws a maximum
of 1 A
AC
at 115 V
AC
.
AC BREAKER –
10-ampere resettable circuit breaker is used to protect against inrush
currents and high current draw from switching power supply. The thermal
circuit breaker is a single pole configuration.
AC ON/OFF -
AC rocker switch (SPST) to supply AC to the AC-DC switching power supply