MEAN WELL
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
SP-500
SERIES
.
LOW COST, HIGH RELIABILITY
.
COMPACT SIZE, LIGHT WEIGHT
.
COOLING FAN ON/OFF AUTOMATICALLY
.
100% FULL LOAD BURN-IN TEST
.
BUILT IN REMOTE CONTRAL
.
105
º
C
OUTPUT CAPACITOR
.
INTERNATIONAL AC INPUT RANGE
.
BUILT IN EMI FILTER, LOW RIPPLE NOISE
.
HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.
BUILT IN PFC CIRCUIT
.
SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.
SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE, OVER TEMP. PROTECTED
MODEL
SPECIFICATION
SP-500-12
SP-500-13.5
SP-500-15
SP-500-24
SP-500-27
SP-500-48
DC OUTPUT VOLTAGE
12V
13.5V
15V
24V
27V
48V
OUTPUT V. TOLERANCE
±1%
±1%
±1%
±1%
±1%
±1%
OUTPUT RATED CURRENT
40A
36A
32A
20A
18A
10A
OUTPUT CURRENT RANGE
0-40A
0-36A
0-32A
0-20A
0-18A
0-10A
RIPPLE & NOISE
240mVp-p
240mVp-p
240mVp-p
240mVp-p
200mVp-p
300mVp-p
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
DC OUTPUT POWER
480W
486W
480W
480W
486W
480W
EFFICIENCY
84%
84%
83%
85.5%
86.5%
87%
DC VOLTAGE ADJ.
10-13.2V
12-15V
13.5-18V
20-26.4V
24-30V
41-56V
INPUT VOLTAGE RANGE
88
~
264VAC
47
~
63Hz;
124
~
370VDC
AC CURRENT
7A/115V
3.5A/230V
POWER FACTOR
0.95/100
~
240VAC
INRUSH CURRENT
18A/115V
36A/230V
LEAKAGE CURRENT
<3.5mA/240VAC
OVERLOAD PROTECTION
105%
~
135%
TYPE:FOLDBACK CURRENT LIMITING
RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION
13.8
~
16.2V
15.5
~
18.2V
18
~
21V
27.6
~
32.4V
31
~
36.5V
57.6
~
67.2V
FAN CONTROL, O.T.P.
RTH1 or RTH2
>=
50
º
C
FAN ON,
<=
45
º
C
FAN OFF,
>=
70
º
C
OUTPUT SHUTDOWN
TEMP. COEFFICIENT
±0.03% /
º
C
(0
~
50
º
C)
SETUP, RISE, HOLD UP TIME
1.5s, 50ms, 20ms
VIBRATION
10
~
500Hz, 2G
10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY
-10
º
C
~
+50
º
C(REFER TO OUTPUT DERATING CURVE), 20%
~
90% RH
STORAGE TEMP., HUMIDITY
-20
º
C
~
+85
º
C, 10%
~
95% RH
DIMENSION
185
*
20
*
93mm
CASE:910
WEIGHT
1.8Kgs
SAFETY STANDARDS
UL1950, TUV EN60950 APPROVED
EMC STANDARDS
CISPR22 (EN55022), IEC1000-4-2,3,4,5,6,8,11 IEC1000-3-2 VERIFICATION
NOTE
:
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25
º
C
70% RH. AMBIENT.
2.TOLERANCE
G
INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 0% TO 100% RATED LOAD.
6.C3,4,14,16,31,32,101,102 MUST BE REMOVED.
7.REFER TO OUTPUT DERATING CURVE VS INPUT VOLTAGE.
JUN.09.98