Device structure / Technical data
•
Installation:
sufficient spacing (250 mm) between the computer unit and possible sour-
ces of electromagnetic interference • Do not connect to the building’s earthing • Select
a good, dry, easily accessible place • Energy-saving mode (display off)
• Individual remote reading with optional plug & play modules (M-bus, pulse)
Installation
General installation instructions
Ö
Observe the environmental conditions!
Ö
Note the cable lengths: Volume measuring section: max. 10 m (use shielded cable),
temperature sensor: max. 10 m.
Securing the computer unit on the wall
Install the computer unit on the wall with the enclosed mounting material.
Installing the temperature sensors
!
Temperature sensors must only be installed as they have been delivered. The
cables may neither be shortened nor extended.
•
The temperature sensor type (Pt 500) must agree with the specifications on the name
plate of the computer unit.
•
Do not lay the temperature sensor cable near cable ducts or channels (min. 300mm).
•
The temperature sensors can be installed in special ball valves or immersion pockets
which are authorised for this type of sensor. – Observe the national regulations.
Be careful to install the temperature sensors symmetrically. Preferably directly immer-
sed.
Directly immersed installation
1
Remove the pressure from the sensor installation location
2
Unscrew the closing screw from the special ball valve.
3
Place the enclosed O-Ring on the assembly pin. Only use one O-Ring.
When replacing sensors, replace the old O-Ring with a new one.
4
Using the assembly pin, turn the O-Ring into the bore hole of the screw plug with a
rotating movement.
5
Place the O-Ring in its final position using the other end of the assembly pin.
6
Place the assembly pin with the sleeve end over the temperature sensor as far as it
will go.
7
Position and attach the attachment screw (plastic nut or brass union piece) on the
temperature sensor.
8
Remove the assembly pin from the temperature sensor.
9
Insert the temperature sensor into the ball valve and tighten the union joint
hand-
tight
.
Installation in immersion pockets
•
Sensor immersion pockets are best installed in T-pieces with 45° or 90° angles. In
the process, the tip of the immersion pockets points against the flow direction and is
located in the middle of the flow.
•
Can only be used in combination with approved immersion pockets !
•
Insert the temperature sensor into the immersion pockets as far as it goes
Summary of Contents for Classic S3
Page 74: ...74 250mm Plug Play M Bus max 10m max 10m Pt 500 300mm 1 2 3 O O 4 5 6 7 8 9 45...
Page 75: ...75 90 2 TH 5 6 TC 7 8 4 1 5 6 2 3 7 8 4 10 open collector 11 Ground 1 2 3 4 5 6...
Page 81: ...81 250 Plug Play M Bus 10 10 Pt 500 300 1 2 3 4 5 6 7 8 9 RU...
Page 82: ...82 45 90 2 TH 5 6 TC 7 8 4 1 5 6 2 3 7 8 4 10 11 1 2 3 4 5 6...
Page 87: ...87 E1 M1 DE 07 MI004 47114711 PT500 PN PS Q K CE M Q Qq C 1 x l S kWh 000...
Page 136: ...136...
Page 137: ...137...
Page 138: ......
Page 139: ......
Page 142: ......
Page 143: ......