background image

 

10 

 

5.2

 

DISPENSING 

5.2.1

 

Pressure Adjustment 
Note: Pressure in Port A is not regulated.  It has the same pressure as the 
supplied pressure.  Port A is used for valve activation pressure. Make sure 
the supplied pressure is set at least 70 psi (4.8 bar). Pressure in Port B is 
regulated.  It provides constant pressure to feed fluid to the valve. 
 

To adjust pressure in port B:

  

  

1.

 

Touch the “Pressure B” icon to enter the pressure setup screen   
 

2.

 

Touch the Up and Down arrows to set desired fluid feed pressure 

 

 

 
 

 

3.

 

Touch the Check Mark icon to save and exit   
 
 

5.2.2

 

To Change Pressure Unit Display 
Note: The default pressure unit is PSI.  To change pressure unit to BAR, 
follow the instructions below. 
 

1.

 

Touch the Setup icon to enter the setup screen 
 

 

 

Summary of Contents for TS555R

Page 1: ...TS555R SMART CONTROLLER FOR PNEUMATIC VALVES User Guide Copyright OK International...

Page 2: ...ay 10 5 2 3 Manual Purge Dispense Cycle 11 5 2 4 Automatic Dispense Cycle 11 5 2 5 Teach Mode Setting 12 5 2 6 To run in Continuous Mode 12 5 3 Stored Program in Memory Cell 14 5 3 1 To store dispense...

Page 3: ...owing actions Making changes to equipment that has not been recommended in the User Guide Using incompatible or damaged replacement parts Using unapproved accessories or auxiliary equipment 1 2 Safety...

Page 4: ...Timed mode Accept change Interrupt mode Pressure calibration Teach mode Save Purge mode Reset time in Teach mode Dispense IP address Login Logout Cancel Run Method Sequence Mode Continuous Mode Sequen...

Page 5: ...allation Category I Indoor Use Altitude up to 2 000m 6 562ft Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 C to 60 C 14 F to 140 F Max Relative Humidity 80 for temperature up...

Page 6: ...nnecting the Unit Refer to Figure 1 0 and 2 0 1 Connect the power cord foot switch to the back of the unit 2 Connect Valve air hose Port A 3 Connect the Fluid pressure hose to Port B 4 Press the Power...

Page 7: ...5 1 1 Login 1 Touch the Login icon to enter the login screen 2 Enter 0000 in Password window The password can be disabled by check the box next to it 3 Touch the Green Check Mark icon to save and exi...

Page 8: ...ed correctly in this menu prior to calibrating the pressure Not doing so may cause the pressure display to show the incorrect pressure 3 Turn pressure adjustment knob counterclockwise until the wheel...

Page 9: ...integrated to any robot automation system A To use as Stand Alone Controller Go to setup screen to check for controlling mode If the icon C is showing then it is already set as stand alone controlling...

Page 10: ...B is regulated It provides constant pressure to feed fluid to the valve To adjust pressure in port B 1 Touch the Pressure B icon to enter the pressure setup screen 2 Touch the Up and Down arrows to se...

Page 11: ...witch to activate the purge dispense cycle Alternately touch and hold the Run icon on the display to activate the purge dispense cycle 5 2 4 Automatic Dispense Cycle Setting 1 Touch the Timed mode ico...

Page 12: ...in determining the required dispense time when the dispense output is known 1 Touch the Teach icon to enter the teach mode 2 Touch the Time Reset icon to set timer to zero 3 Press and hold down the f...

Page 13: ...13 5 3 2 To run in Continuous Mode The controller can be setup to repeat the run continuously 1 Touch the Setup icon to enter the setup screen 2 Touch the Run Method icon...

Page 14: ...he X icon to exit The screen will look similarly to the screen below Note If the controller is set to activate memory cell 1 and the delay time is set at 5000 ms the controller will activate memory 1...

Page 15: ...ok similarly to the screen below Notes A If there is no delay time entered in the setting the operator has to press the foot switch or touch the Run icon after each memory cell is completed to activat...

Page 16: ...ote If the sequence mode is set to activate memory cells 1 3 and the delay time is set at 5000 ms the controller will activate memory 1 to 3 continuously with 5000 ms delay between each activation The...

Page 17: ...to confirm 4 Touch the X icon to exit 5 5 To Change Password Note The default password is 0000 To change the password follow the instructions below 1 Touch the Login icon to enter the login screen 2...

Page 18: ...the old password then enter the new password 4 Touch the Check Mark icon to save 5 Touch the X icon to exit Note 1 The password can be disable by check box next to Disable Password 2 The master passwo...

Page 19: ...focus mainly on copying the following files to your computer a The portal exe file b The timezone zip file 2 Create a new folder and name IoT or any desired name 3 Copy the portal exe file and the ti...

Page 20: ...20 7 Type cd iot then press the Enter button 8 Type set OKI_IOT_PREFIX MyPrefix then press the Enter button...

Page 21: ...ipconfig then press the Enter button 11 Record the Server IPv4 address show in the IPv4 Address line on the above screen For this example the Server IP address is 172 16 40 91 This address will be ent...

Page 22: ...ny web browser 14 Type in http localhost 8090 then press the enter button You are now in the webserver site The below screen will be displayed 15 Click the Login button 16 Enter admin in the Login box...

Page 23: ...v4 address recorded in step 11 into Remote IP address box 20 Touch the Check Mark icon to save 21 The controller is now connected to the webserver site 6 2 Making Parameters Adjustment from the websev...

Page 24: ...e controller parameters such as pressure and dispense time can be adjusted from the webserver Click on the Edit icon The parameter screen will appear as shown below Proceed to make changes Click OK bu...

Page 25: ...he unit 4 Turn on the unit 5 Wait while the system is loading the new software This process can take a few minutes 6 Wait until the system completes the software update from the USB drive and the firs...

Page 26: ...26 9 Wait until the system completes the rebooting sequence and the home screen is displayed 10 Repeat sections 5 1 1 and 5 1 2 to re calibrate the air pressure...

Page 27: ...ective PC board Increase supplied pressure Check foot switch connection Foot switch needs to be repaired or replaced Unplug power cord and disconnect air supply Remove cover and check for broken wires...

Page 28: ...national s option free of charge Customer with defective product under warranty must contact the nearest OK International office or distributor to secure a return authorization prior to shipping the p...

Page 29: ...within a 5 to 24 VDC range and a maximum of 250 mA Note During the dispense cycle pin 3 will be grounded Please make sure the external device your machine that controls the dispenser controller has t...

Reviews: