TECHCON SYSTEMS TS550R User Manual Download Page 3

 

30

9.

 

MAINTENANCE  

The dispenser is designed and built to be relatively maintenance free.  To assure 
trouble free operation, please follow below steps: 

1.

 

Make certain air supply is clean and dry. 

2.

 

Avoid connecting the unit to excessive moisture or solvent saturation 

3.

 

Avoid connecting air supply exceeding 100 psi (6.9 bars) 

4.

 

Use only Amyl Alcohol to clean outside surface of the main housing 

5.

 

Use only soft cloth to clean the display screen 

 

 

10.

 

LIMITED WARRANTY 

OK International warrants this product to the original purchaser for a period of 2 
years from date of purchase to be free from material and workmanship defects but 
not normal wear-and-tear, abuse and faulty installation.  Defective product or 
subassembly and components under warranty will be repaired or replaced (at OK 
International's option) free of charge. Customer with defective product under 
warranty must contact the nearest OK International office or distributor to secure a 
return authorization prior to shipping the product to the assigned OK International 
authorized service center.  For nearest OK International office or distributor 
contact information, please visit www.techconsystems.com.   OK  International 
reserves the right to make engineering product changes without notice. 

 
 

All returns must be issued with a Returns Authorization number, prior to return. 
Send warranty returns to: 

 

Americas 

OK International  

           10800 Valley View Street 
           Cypress, CA 90630 
 

 

+1 714 230 2398 

 

 

Europe 

OK International 
Eagle Close Chandler’s Ford Ind Est 
Eastleigh, Hampshire 
SO53 4NF 
United Kingdom 
+44 2380 489 100

 

 

 

Asia  

Dover (Shenzhen) Industrial 
Equipment Manufacturing Co., LTD. 
4th Floor East, Electronic Building 
Yanxiang Industrial Zone, High Tech Road 
Guangmin New District 
Shenzhen, P.R.C 
+86 21 64952662   

 

www.techconsystems.com

 

 

 

3

1.

 

SAFETY 

1.1

 

Intended Use: 

WARNING: Use of this equipment in ways other than those described in this User 
Guide may result in injury to persons or damage to property. Use this equipment 
only as described in this User Guide. 

OK International cannot be responsible for injuries or damages resulting from 
unintended applications of its equipment.  Unintended uses may result form taking 
the following actions: 

 

Making changes to equipment that has not been recommended in the User 
Guide 

 

Using incompatible or damaged replacement parts 

 

Using unapproved accessories or auxiliary equipment 

 

1.2

 

Safety Precautions: 

 

Do not operate this unit in excess of maximum ratings/settings 

 

Always wear appropriate personal protective clothing or apparel 

 

The fluid being dispensed may be toxic and/or hazardous.  Refer to Material 
Safety Data Sheet for proper handling and safety precautions 

 

Do not smoke or use open flame when flammable materials are being dispensed 

 

This equipment is for indoor use only 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for TS550R

Page 1: ...TS550R SMART CONTROLLER FOR PNEUMATIC VALVES User Guide Copyright OK International...

Page 2: ...CYCLE FEEDBACK During a dispense cycle an open collector circuit closes and remains closed while the valve is dispensing Pin 3 and 4 can be as feedback signal to synchronize with other devices Power f...

Page 3: ...ith a Returns Authorization number prior to return Send warranty returns to Americas OK International 10800 Valley View Street Cypress CA 90630 1 714 230 2398 Europe OK International Eagle Close Chand...

Page 4: ...not actuate Supplied pressure dropped below Low Pressure setting Foot switch not plugged in or improperly plugged in Defective foot switch Broken wire or loose connection inside unit Defective solenoi...

Page 5: ...NA POWER SWITCH AIR INLET AIR OUTLET UNREGULATED FOOT SWITCH PORT POWER INLET IO PORT INTERNET PORT USB PORT GROUNDING TS560R 3 SPECIFICATIONS 4 FEATURES Figure 1 0 Size 290mm x 212mm x 98mm 11 4 X 8...

Page 6: ...d 3 Pressure Pot not included 4 Display 5 Power Adapter 6 Foot Switch 27 Proceed to make changes Click OK button to save The new parameters will be displayed on the controller 7 SOFTWARE UPGRADE Note...

Page 7: ...The controller parameters such as pressure and dispense time can be adjusted from the webserver Click on the Edit icon The parameter screen will appear as shown below 7 5 1 1 Login 1 Touch the Login...

Page 8: ...to 100 Note The digital values shown at 0 and 100 icons are for reference only The actual calibrated values will be different 9 Touch the Reboot icon to save the settings and reboot the system 10 Wai...

Page 9: ...Port A and Port B delivers the same output pressure This pressure is to activate the valve Make sure the supplied pressure is set at least 70 psi 4 8 bar 1 Touch the Pressure A B icon to enter the pr...

Page 10: ...uch the Timed mode icon to set the dispense cycle in pre set dispense time The icon should turn to green color 2 Touch the Dispense icon to enter the setup screen 3 Touch the Up and Down arrows to set...

Page 11: ...uld turn to green color 5 2 5 Teach Mode Setting In the teach mode the dispense time will be accumulated as long as the foot switch is depressed This is helpful in determining the required dispense ti...

Page 12: ...memory 1 continuously with 5000 ms delay between each activation 21 6 INTERNET of Thing IoT 6 1 Setup webserver on the computer 1 Go to Techcon Website www techconsystems com and download the followi...

Page 13: ...12 Touch X icon to save and exit 13 Touch the IP Address icon and the unit will show an IP address Note Once the unit is turned off the Wi Fi connection is lost To re connect the unit back to the sam...

Page 14: ...dispense parameters then touch the Save icon to save the data 5 4 2 To run in Single Sequence Mode 1 Touch the Run Method icon to enter sequence mode setup 19 5 7 To Connect to Wi Fi network 1 Connec...

Page 15: ...Mode icon 4 Touch the Check Mark icon to save 5 Touch the X icon to exit The screen will look similarly to the screen below Notes A If there is no delay time entered in the setting the operator has t...

Page 16: ...ms the controller will activate memory 1 to 3 continuously with 5000 ms delay between each activation 5 5 Cycle Counter The cycle counter records the numbers of automatic dispense cycle being activate...

Reviews: