Fuse
The regulator has a WT 6,3A tube fuse-link (5x20mm) protecting the network.
NOTE
Higher amperage fuse should not be used as it may damage the controller.
XIII.
SOFTWARE UPDATE
In order to install new software, the controller must be unplugged from the power supply. Next, insert the memory stick with
the new software into the USB port. Connect the controller to the power supply at the same time holding EXIT button. It is
necessary to hold EXIT button until a single sound signal is heard – it signalises that the software update process has been
initiated. After it has been completed, the controller restarts automatically.
NOTE
Software update shall be conducted only by a qualified fitter. After the software has been updated, it is not possible
to restore previous settings.
NOTE
Do not switch the controller off while updating the software.
XIV.
TECHNICAL DATA
Supply voltage
230V +/-10% / 50Hz
Maximum power consumption
6 W
Operation temperature
5
0
÷50
0
C
1-8 outputs load
0,3 A
Pump output load
0,5 A
Potential-free contact max. output load
1A
Frequency
868MHz
Fuse link
6,3 A