 – pre-programmed change from economical temperature to comfort temperature 

Activating  this  function  means  that  at  the  time  of  pre-programmed  change  of  the  pre-set 
temperature from comfort to economical or the other way round, the current room temperature 
is close to the desired value.  
 
In order to configure this parameter, press  or   
until 

Optimum start

 setting panel appears on the 

screen.  
Use 

+

 or 

-

 to activate or deactivate 

Optimum start

 

function. Press 

 to confirm and move on to edit 

the  next  parameter  or  press  and  hold    MENU  to 
confirm and return to the main screen view. 
 

 

 

VII.c.7) Service menu 

Certain functions in the controller service menu are 
secured  with  a  code.  In  order  to  adjust  their 
parameters,  press 

or 

  until  Service  menu 

settings appear on the screen.  
To view the service menu it is necessary to enter 
the code – 215.  Use 

+

 or 

 to select the first digit 

(2) and press MENU to confirm. Follow the same 
steps selecting the remaining two digits.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Room temperature -  

OPTIMUM START switched on: 

Room temperature -  

OPTIMUM START switched off: 

Summary of Contents for EU-290 v1

Page 1: ...EU 290 user s manual 1 User s manual EU 290 v1 4 ...

Page 2: ... b Operation modes 10 VII b Main screen view and description 12 VII c Controller functions 14 VII c 1 Block diagram main menu 14 VII c 2 Day of the week 15 VII c 3 Time settings 15 VII c 4 Day from 15 VII c 5 Night from 15 VII c 6 Optimum start 15 VII c 7 Service menu 16 VII c 8 Weekly control 18 VII c 9 Pre set comfort temperature 20 VII c 10 Pre set economical temperature 20 VII c 11 Pre set tem...

Page 3: ... property WARNING The device should be installed by a qualified electrician The regulator should not be operated by children WARNING Any use other than specified by the manufacturer is forbidden Before and during the heating season the controller should be checked for condition of its cables The user should also check if the controller is properly mounted and clean it if dusty or dirty Care for th...

Page 4: ...the pre set room temperature manual mode day night program weekly control Controller equipment touch buttons front panel made of 3mm glass built in temperature sensor batteries Controller versions v1 wired without backlight v2 wireless with temporary backlight It may be optionally equipped with a wireless external sensor This controller version cooperates with an additional signal receiver install...

Page 5: ...I a Connection diagrams v1 and v3 versions The room regulator should be connected to the heating device via a two core cable as illustrated in the diagrams below 1 Diagram EU 290 regulator connected directly to the heating device 2 Diagram EU 290 regulator connected to the CH boiler controller ...

Page 6: ...290 regulator connected to the heating device with load up to 1A 4 Diagram EU 290 room regulator connected to the heating device with load above 1A 5 Diagram EU 290 room regulator connected to a three phase heating device ...

Page 7: ...the following control lights green 1 indicates data reception goes on during channel change red indicates receiver operation green 2 goes on when the room temperature fails to reach the pre set temperature the heating device is switched on How to change the communication channel Channel 35 is the default communication channel in the room regulator The channel may be easily changed if the current c...

Page 8: ... set 0 as the first digit Example 1 28 is the desired communication channel In order to select this channel set the first digit 2 and the second digit 8 Press and hold the channel change button the control light flashes quickly once the process of channel change has been initiated Hold the button and wait until the light flashes two more times the first digit of the channel number 28 Release the b...

Page 9: ...o select a different channel EU 290 v4 In order for the controller to operate correctly the user must follow these steps when starting the device for the first time 1 Insert the batteries 2 Check if the current communication channel selected in the regulator is the same as in the external controller 35 is the default communication channel in all devices If there is a conflict with other devices us...

Page 10: ...ature and the pre set economical temperature will apply The user may set 9 different programs divided into three groups programs 1 3 daily temperature values are set for all days of the week programs 4 6 daily temperature values are set separately for the weekdays Monday Friday and for the weekend Saturday Sunday programs 7 9 daily temperature values are set for each day of the week separately The...

Page 11: ...n Day night mode is active the user changes the pre set temperature by pressing or which automatically activates manual mode The controller returns to Day night mode when daytime changes into nighttime or the other way round or when the user presses Example 2 manual mode activation in weekly control mode When weekly control is active the user changes the pre set temperature by pressing or which au...

Page 12: ...ature After entering the menu this button is used to adjust parameters enter the service code etc 4 MENU button hold this button in order to enter the controller menu While editing parameters press and hold this button to confirm the changes and return to main screen view 5 Plus button pressing this button in the main screen view activates manual mode and increases the pre set temperature After en...

Page 13: ...nly when the wireless version of the controller EU 290v2 EU 290v4 is used together with the external temperature sensor 8 Pre set temperature of the room 9 Time 10 Battery level 11 Temperature information depending on the current operation mode o heating mode the icon is flashing when the pre set temperature of the room has not been reached and it is steady when the pre set temperature has been re...

Page 14: ...ller functions The edited parameter is flashing whereas the remaining parameters are not displayed Use and to change the parameter settings Press to confirm the changes and move on to edit the next parameter or press and hold MENU to confirm the changes and return to the main screen view except for editing weekly control and channel selection VII c 1 Block diagram main menu Main menu Day of the we...

Page 15: ...return to the main screen view VII c 5 Night from This function enables the user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press or until Night from setting appears on the screen By pressing or set the hour and minute of night mode activation Press to confirm and move on to the next para...

Page 16: ...r deactivate Optimum start function Press to confirm and move on to edit the next parameter or press and hold MENU to confirm and return to the main screen view VII c 7 Service menu Certain functions in the controller service menu are secured with a code In order to adjust their parameters press or until Service menu settings appear on the screen To view the service menu it is necessary to enter t...

Page 17: ...eceiver and also in the external sensor if it is used Channel 35 is the default communication channel in all devices The channel should be changed only if the current channel is used by other devices In order to change press or until the channel change panel appears on the screen Use and to select the channel Press to confirm and move on to the next parameter or press and hold MENU to confirm and ...

Page 18: ...main screen view How to configure a given weekly program Weekly program enables the user to select the hours when the pre set comfort temperature and the pre set economical temperature will apply Depending on the program number the user may assign daily settings to all days of the week programs 1 3 separately for working days and the weekend programs 4 6 and separately for each day of the week pro...

Page 19: ...ss or in order to select a day Step 3 assign comfort temperature or economical temperature to particular hours An hour which is being edited is displayed on the controller screen In order to assign comfort temperature press In order to select economical temperature press The controller automatically moves on to editing the next hour The parameters of the weekly program are displayed at the bottom ...

Page 20: ...nomical temperature Pre set economical temperature is used in weekly control mode and day night mode Press or button until the economical temperature change panel appears on the screen Press or to set the desired temperature Press to confirm and move on to the next parameter or press and hold MENU to confirm and return to the main screen view VII c 11 Pre set temperature hysteresis Room temperatur...

Page 21: ...om 10 C to 10 C with the accuracy of 0 1 C Press or until the sensor calibration panel appears on the screen Use and to define correction Press to confirm and move on to edit the next parameter or press and hold MENU to confirm and return to the main screen view VIII Technical data Range of room temperature setting 5o C 35o C Supply voltage Batteries 2xAA 1 5V Accuracy of measurement 1o C Contact ...

Page 22: ...tage Directive LVD 2006 95 EC an act of April 13 2007 concerning Electromagnetic Compatibility Journal of Laws 07 82 556 implementing provisions of EMC directive 2004 108 EC the regulation by the Ministry of Economy of May 8 2013 concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment implementing provisions...

Page 23: ...EU 290 user s manual 23 ...

Page 24: ...TECH 24 ...

Reviews: