EU-290 user’s manual
15
VII.c.2) Day of the week
After entering the main menu, all icons which are not
connected with the parameter which is being edited
are not displayed. The first parameter is day of the
week.
Press
+
or
-
until the current day of the week appears
on the screen. Press
to confirm and move on to
the next parameter or press and hold MENU to
confirm and return to the main screen view.
VII.c.3) Time settings
In order to set current time, press
or
until
time setting panel is displayed on the screen.
By pressing
+
or
-
set the hour and minutes. Press
to confirm and move on to the next parameter
or press and hold MENU to confirm and return to
the main screen view.
VII.c.4) Day from...
This function enables the user to define the exact
time of entering the day mode. When Day/night
mode is active, comfort temperature applies at
daytime.
To configure this parameter press
or
until
Day from…
setting appears on the screen.
By pressing
+
or
-
set the hour and minute of day
mode activation.
Press
to confirm and move on to the next
parameter or press and hold MENU to confirm and
return to the main screen view.
VII.c.5) Night from…
This function enables the user to define the exact
time of entering the night mode. When Day/night
mode is active, economical temperature applies
at nighttime.
To configure this parameter press
or
until
Night from…
setting appears on the screen.
By pressing
+
or
-
set the hour and minute of
night mode activation.
Press
to confirm and move on to the next
parameter or press and hold MENU to confirm and
return to the main screen view.
VII.c.6) Optimum start
Optimum start is an intelligent system controlling the heating/cooling process. It involves constant
monitoring of the heating/cooling system efficiency and using the information to activate the
heating/cooling process in advance in order to reach the pre-set temperatures.
The system requires no user intervention. It precisely reacts to any changes that affect
the efficiency of the heating system. If, for example, some changes have been introduced to the
heating system and the house heats up faster than before, the Optimum start system will
recognize the changes at the next pre-programmed temperature change (from comfort to
economical) and in the next cycle the heating system activation will be adequately delayed,
reducing the time needed to reach the desired temperature.