![Tech Works MC-IP Series Manual Download Page 12](http://html1.mh-extra.com/html/tech-works/mc-ip-series/mc-ip-series_manual_1066286012.webp)
1/24/2021
Tech Works MC-IP-Series System Planning & Installation Manual
Page 12 of 32
MC-IP-116 Connections
All system components employ RJ45 connectors for a couple of purposes
1. For connection of Tech Works PA-Buss components such as the PA-402
2. For connection of components to the IP Network
Either application assumes standard off the shelf CAT6 cables wired to EIA/TIA 568B
Power connections are on both the Euro Style Screw Block and the
2.00mm ID (0.079"),
5.50mm OD (0.217") Barrel connector for 24 VDC.
Screw terminal power connections are always:
+24VDC
COMMON
CHASSIS
External Paging Amplifier connections are always:
Audio (+)
Audio (
-
)
Station field wiring is a 4 or 6-conductor compression clamp connector with 0.1 inch spacing and will
connect to 18-24 AWG wire. Wires must be stripped of insulation approximately ¼ inch from the end
before being inserted in the connector. A slot above each connection allows the insertion of a 2.0 mm
tech blade screw driver to release the clamp so that you can remove the wire if necessary.
Remote Station connections are:
If this is an MC-IP-116-L there will be
2 additional terminals
SPEAKER (
-
)
SPEAKER (+)
SHIELD
CALL SWITCH
LED POWER (+)
LED POWER (
-)