Connect the red and black wires from the column top
respectively to the red and black wires in the column
base by inserting them into an open port in wire
connectors. Close the levers to lock the wires in place.

Connect the fixture to a suitable ground in accordance
with local electrical codes.

Connect the neutral power line wire to terminal block
connected to the white wires.

Connect the hot power line wire to terminal block
connected to the black wires.

Use the gray and purple dimming wires for 0-10v
dimming application (if not in use, make sure to cap
these wires off).

Reinstall the access panel (reversal of section 2A).

6

7

Warning:

The purple and gray wires are only used for 0-

10v dimming. For all other applications, do not connect
the gray and purple wires.

8

2A

Loosen

the access panel set screw on

(Do Not Remove)

column base with the provided Allen wrench.

Pull away the top of the access panel and lift it
completely out the column base.

Power the fixture using the following steps or wiring
diagrams according to the options included with the
fixture.

1

2

Wire the Column

5

6

7

8

4

4

2B

9

For Standard options, go to step 2B.

For Photocell/Surge options, go to step 2C.

For In-line Fuse/Surge options, go to step 2D.

For Photocell/In-line Fuse/Surge options, go to step 2D.

3

Summary of Contents for 700OCTUR

Page 1: ...um 90 c supply conductors OUTDOOR Install the Column 2 3 Bring the power wires to the fixture location in accordance with local electrical codes Mount the base plate to an even and smooth surface using the provided template on page 3 NOTE anchor lag bolts nuts and washers not provided 1B 2 3 3 1C Align the tab on the column top to the slot in the column base insert the fixture wires into the colum...

Page 2: ...in use make sure to cap these wires off Reinstall the access panel reversal of section 2A 6 7 Warning The purple and gray wires are only used for 0 10v dimming For all other applications do not connect the gray and purple wires 8 2A Loosen the access panel set screw on Do Not Remove column base with the provided Allen wrench Pull away the top of the access panel and lift it completely out the colu...

Page 3: ...rating correctly make sure to check the fuse 12 Use the gray and purple dimming wires for 0 10v dimming application if not in use make sure to cap these wires off Reinstall the access panel reversal of section 2A 13 2E Note for In Line Fuse equipped fixtures in the case that the fixture is not operating correctly make sure to check the fuse Note for Photocell equipped fixtures at initial power up ...

Page 4: ...raphic is a registered trademark of Tech Lighting L L C Tech Lighting reserves the right to change specifications for product improvements without notification A Generation Brands Company SAVE THESE INSTRUCTIONS 4 TURBO COLUMN MOUNTING PLATE TEMPLATE WARNING If printing this template ensure printer settings are set to actual size ...

Reviews: