3

C

O

M

X

4

X

3

X

2

X

1

120 VOLT
TERMINAL BLOCK

HOT POWER LINE WIRE

NEUTRAL POWER LINE WIRE

Install the 120 volt power line wires to the transformer.

Insert the hot power line wire inline with the black 
transformer wire into the terminal block and tighten the 
screw.

Insert the neutral power line wire inline with the white 
transformer wire into the terminal block and tighten the 
screw.

Ground the transformer housing in accordance with 
local electrical codes.

Connect the 120 Volt Wires

Check the System

C

O

M

X

4

X

3

X

2

X

1

COVER

After installing the entire low voltage system, if the 
lamps have low intensity, then measure the voltage at 
the fixture closest to the power feed contacts with a 
voltmeter. The system must be at least 80% loaded 
and the voltmeter should read between 11V - 12V 
~AC. If the voltage does not fall in this range, call 
Tech Lighting "Technical Support" at 847-410-4606.

Operate the system for five minutes. On the low 
voltage side, all electrical connection spots should be 
cool to the touch. If a connection is hot to the touch, 
retighten the connection and check to ensure that the 
temperature decreases.

Place the transformer cover and tighten all four 
provided Phillips screws on the front.

3A

2

3

4

1

1

2

3

4

4A

SCREW

2

3

1

3

3

3

3

Summary of Contents for 700AT300TR

Page 1: ...only This product may be dimmed only with a low voltage magnetic dimmer Using a dimmer not designed for low voltage magnetic applications may work initially but will eventually cause transformer failure and will void the warranty The dimmer must be derated as indicated by the dimmer manufacturer This product is intended for use with Tech Lighting low voltage lighting systems only During installati...

Page 2: ... the primary power line coming into the transformer If the voltage is not in the range of 115 120 volt then pick the proper terminal tap using the Terminal Tap Table to reconnect the second low voltage wire Install drywall NOTE Other wire sizes that comply with electrical code can be used but may result in an increased voltage drop and reduced lamp intensity NOTE The THHN wire sizes are for 3 drop...

Page 3: ...ER After installing the entire low voltage system if the lamps have low intensity then measure the voltage at the fixture closest to the power feed contacts with a voltmeter The system must be at least 80 loaded and the voltmeter should read between 11V 12V AC If the voltage does not fall in this range call Tech Lighting Technical Support at 847 410 4606 Operate the system for five minutes On the ...

Page 4: ... way The fixtures used with the system must be identified to be used with the corresponding system Minimum volume of the electrical box must be 6 cubic inches 98 cubic centimeter The system is ETL listed for USA and Canada only when all the products used are supplied by Tech Lighting It is important to wire the remote transformer for the system as described in these instructions Load the circuit o...

Reviews: