2

Install the Transformer

Select the location between the studs (16" apart) where 
the transformer is to be mounted.

Place the transformer between the studs and fasten it to 
the studs through the bracket holes with four #8 or 
#10 screws (not provided).

STUD

SCREW

BRACKET

C

O

M

X

4

X

3

X

2

X

1

C

O

M

X

4

X

3

X

2

X

1

Install two low voltage wires from the transformer to 
the electrical power feed box to which the power feed 
canopy will be attached. Run the proper size wire using 
the low voltage wire size table.

LOW VOLTAGE WIRES

Insert one low voltage wire into the secondary terminal 
marked "COM" and tighten the screw firmly.

Insert the second low voltage wire to the "X2" tap 
terminal (default) and tighten the screw firmly.

Measure the voltage at the primary power line coming 
into the transformer. If the voltage is not in the range 
of 115 - 120 volt, then pick the proper terminal tap 
using the "Terminal Tap Table" to reconnect the second 
low voltage wire.

Install drywall.

NOTE:

 

Other wire sizes that comply with electrical 

code can be used, but may result in an increased 
voltage drop and reduced lamp intensity.

NOTE:

 

The THHN wire sizes are for 3% drop in 

voltage based on 300 watt loads. Lengths are the 
distance from the transformer to the system power 
feed connector.

TRANSFORMER
WATTAGE

WIRE SIZE
FOR 5 FT

WIRE SIZE
FOR 6-15 FT

WIRE SIZE
FOR 16-20 FT

WIRE SIZE
FOR 21-40 FT

WIRE SIZE
FOR 40-60 FT

WIRE SIZE
FOR 61-90 FT

300 WATT

#6 GA

#4 GA

#1 GA

#1/0 GA

#3/0 GA

#10 GA

LOW VOLTAGE WIRE SIZE TABLE

Connect the 12 Volt Low Voltage
Wires

PRIMARY POWER
LINE VOLTAGE

105 - 109

TERMINAL TAP TABLE

110 - 114

115 - 120

121 - 125

TERMINAL TAP
TO BE USED

X4

X3

X2

X1

1A

1

2

1

2

3

2

2A

4

5

1

2

3

Summary of Contents for 700AT300TR

Page 1: ...only This product may be dimmed only with a low voltage magnetic dimmer Using a dimmer not designed for low voltage magnetic applications may work initially but will eventually cause transformer failure and will void the warranty The dimmer must be derated as indicated by the dimmer manufacturer This product is intended for use with Tech Lighting low voltage lighting systems only During installati...

Page 2: ... the primary power line coming into the transformer If the voltage is not in the range of 115 120 volt then pick the proper terminal tap using the Terminal Tap Table to reconnect the second low voltage wire Install drywall NOTE Other wire sizes that comply with electrical code can be used but may result in an increased voltage drop and reduced lamp intensity NOTE The THHN wire sizes are for 3 drop...

Page 3: ...ER After installing the entire low voltage system if the lamps have low intensity then measure the voltage at the fixture closest to the power feed contacts with a voltmeter The system must be at least 80 loaded and the voltmeter should read between 11V 12V AC If the voltage does not fall in this range call Tech Lighting Technical Support at 847 410 4606 Operate the system for five minutes On the ...

Page 4: ... way The fixtures used with the system must be identified to be used with the corresponding system Minimum volume of the electrical box must be 6 cubic inches 98 cubic centimeter The system is ETL listed for USA and Canada only when all the products used are supplied by Tech Lighting It is important to wire the remote transformer for the system as described in these instructions Load the circuit o...

Reviews: