Tech Controllers EU-L-X WiFi User Manual Download Page 28

 

- Inappropriate valve on the 
radiator

 

 

ERROR #3 

- The valve got stuck  
- Inappropriate valve on the 
radiator 
- Too little stroke (movement) of 
the valve 

 

- Inspect the valve operation  
- Replace the valve on the radiator  
- Check the valve stroke 

 

ERROR #4 

- No range  
- No batteries  
 
 
 
 

 

- Check the distance between the 
actuator and the controller 
- Insert batteries into the actuator  
After the communication is re-
established, the alarm is deactivated 
automatically.  

 

STT-869 actuator alarm 

ERROR #1 - Calibration error 1 

 

Moving the screw to the mounting 
position took too much time

 

- The limit switch sensor is damaged 

 

- Calibrate actuator again by holding the 
communication  button  until  the  third 
flash of green light 
- Call the service staff

 

ERROR #2 - Calibration error 2 

 The 

screw is maximally pulled out. No 
resistance while pulling out 

 

- The actuator has not been 
screwed to the valve or has not 
been screwed completely  
- The valve stroke is too big or the 
valve dimensions are not typical  
- Actuator current sensor is 
damaged 

 

-  Check  if  the  controller  has  been 
installed properly 
- Replace the batteries 
- Calibrate actuator again by holding the 
communication  button  until  the  third 
flash of green light 
- Call the service staff

 

ERROR #3 - Calibration error 3 - The 
screw has not been pulled out enough 
- the screw meets resistance too early 

 

- The valve stroke is too small or the 
valve dimensions are not typical  
- Actuator current sensor is 
damaged  - Low battery level 

 

- Replace the batteries  
- Contact the service staff 

 

ERROR #4 - No feedback 

 

- The master controller is switched 
off  
- Poor range or no range to connect 
with the master controller  
- Radio module in the actuator is 
damaged 

 

- Check if the master controller is on 
-  Reduce  the  distance  from  the  master 
controller 
- Call the service staff

 

ERROR #5 - Low battery level 

 

The battery is flat 

 

Replace the batteries 

 

ERROR #6 - Encoder is locked 

 

The encoder is damaged 

 

- Calibrate actuator again by holding the 
communication  button  until  the  third 
flash of green light 
- Call the service staff

 

ERROR #7 - To high voltage 

 

- Unevenness of the screw, the 
thread etc. may cause excessive  
resistance  
- Too high resistance of gear or 
motor  
- Current sensor is damaged 

 

ERROR #8 - Limit switch sensor error 

 

Limit switch sensor damaged 

 

 

 

Summary of Contents for EU-L-X WiFi

Page 1: ...EU L X WiFi...

Page 2: ...4 5 Manual mode 25 4 6 External sensor 25 4 7 heating stopping 25 4 8 Potential free contact 26 4 9 Pump 26 4 10 Heating cooling 26 4 11 Anti stop settings 26 4 12 Maximum humidity 26 4 13 Language 2...

Page 3: ...The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than spe...

Page 4: ...number of functions support for EU R 12b EU R 12s and EU F 12b cable regulators support for floor temperature sensors support for external sensors and weather controls support for wireless window sens...

Page 5: ......

Page 6: ...connections Before working on the controller disconnect its power supply and secure it against accidental switching on CAUTION Incorrect wiring may damage the controller An illustrative diagram showi...

Page 7: ...d into the right terminal of the sensor connector as seen from the front of the controller and depicted in attached images The second terminal of the capacitor is screwed into the terminal of the left...

Page 8: ...r in the ON position in the controller and the last of the regulators When connecting regulators to a controller located in the middle of the transmission line terminate switch the jumper to the ON po...

Page 9: ...ime can be adjusted from the network automatically Step 4 Configure temperature sensors room regulators In order for the EU L X WiFi controller to support a given zone it must receive information abou...

Page 10: ...s the operation parameters between the zones 3 button used to browse the menu functions or increase the value of the edited parameters This button also switches the operation parameters between the zo...

Page 11: ...cooling depending on the mode the digit flashes If an alarm occurs in a given zone an exclamation mark will be displayed instead of a digit To view the current operating parameters of a specific zone...

Page 12: ...ature The set temperature in the zone results from the settings of a specific mode of operation in the zone i e the weekly schedule However it is possible to turn off the schedule and set a separate t...

Page 13: ...ing the MENU button Use the MENU button to go to the settings of the time intervals and the set temperature that will be valid for the specified time interval set it using the arrows confirm with the...

Page 14: ...steresis is 1 C The room sensor will start to indicate room underheating after the temperature drops to 22 C Calibration Room sensor calibration is carried out during assembly or after a longer period...

Page 15: ...s information to automatically activate the heating in advance of the time required to reach the set temperatures This system does not require any involvement on the part of the user and precisely res...

Page 16: ...n the zone temperature reaches the set point Once the set point is reached the temperature in the zone will start to drop When it reaches 21 C set temperature minus hysteresis value the actuator will...

Page 17: ...tration an additional Information function appears where the user can view the sensor parameters e g battery status range etc It is also possible to delete a given sensor or all at the same time 4 1 8...

Page 18: ...llation from overheating 4 2 ADDITIONAL CONTACTS The function allows you to handle additional contacts First of all it is necessary to register such a contact 1 6 pcs To do this select the Registratio...

Page 19: ...e Calibration This function can be used to calibrate the built in valve e g after prolonged use During calibration the valve is set to a safe position i e for the CH valve and the Return protection ty...

Page 20: ...y in a short circuit while the full opening of the valve 100 means that the short circuit is closed and the water flows through the entire central heating system CAUTION If the Boiler Protection is of...

Page 21: ...When this function is checked the controller will operate according to the Room regulator temperature lower parameter Room regulator temp lower In this setting set the value by which the valve will l...

Page 22: ...take into account the Self of the valve module or the Main sensor Only in slave mode Boiler protection This provides protection against excessive CH temperature and is intended to prevent dangerous i...

Page 23: ...e deviations set are in the range of 10 C To enable weekly control select and check Mode 1 or Mode 2 Detailed settings of these modes can be found in the following sections of the submenu Set Mode 1 a...

Page 24: ...on The user can control the operation of various devices and change some parameters using the emodul pl application The device has a built in Internet module After switching on the Internet module and...

Page 25: ...to 10 C with a step of 0 1 C In the case of a wireless sensor the subsequent parameters relate to the range and level of the battery 4 7 HEATING STOPPING Function to prevent actuators from turning on...

Page 26: ...operating mode Heating all zones are heated Cooling all zones are cooled Automatic the controller switches the mode between heating and cooling based on the two state input 4 11 ANTI STOP SETTINGS Thi...

Page 27: ...sensor Replace the sensor with a new one or contact the service staff if necessary No communication with sensor wireless regulator No range No battery Flat battery Put the sensor regulator in a differ...

Page 28: ...the controller has been installed properly Replace the batteries Calibrate actuator again by holding the communication button until the third flash of green light Call the service staff ERROR 3 Calib...

Page 29: ...arried out by a qualified installer After changing the software it is not possible to restore the previous settings Do not turn off the controller while updating the software IX TECHNICAL DATA AC1 loa...

Page 30: ...equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011 65 EU on the restriction of the use of certain ha...

Page 31: ......

Page 32: ......

Reviews: