![Tech Controllers EU-L-X WiFi User Manual Download Page 15](http://html1.mh-extra.com/html/tech-controllers/eu-l-x-wifi/eu-l-x-wifi_user-manual_829306015.webp)
4.1.5.
SETTINGS
➢
Weather control
- the option to turn the weather control on/off.
CAUTION
Weather control works only if in the
Menu → Fitter’s
menu
→ External sensor
,
the
Weather control
option was
checked.
➢
Heating
–
the function enables/disables the heating function. There is also a selection of a schedule that will be
valid for the zone during heating and for editing of a separate constant temperature.
➢
Cooling
- this function enables/disables the cooling function. There is also a selection of a schedule that will be
valid in the zone during cooling and editing of a separate constant temperature.
➢
Temperature settings
–
the function is used to set the temperature for the three operating modes (Holiday
mode, Economy mode, Comfort mode).
➢
Optimum start
Optimum start is an intelligent heating control system. It enables continuous monitoring of the heating system and the use
of this information to automatically activate the heating in advance of the time required to reach the set temperatures.
This system does not require any involvement on the part of the user and precisely responds to any changes that affect the
efficiency of the heating system. If, for example, there are changes made to the installation and the house warms up faster,
the optimum start system will identify the change at the next programmed temperature change resulting from the schedule,
and in the subsequent cycle it will delay the activation of the heating until the last moment, reducing the time required to
reach the preset temperature.
A
–
programmed moment of changing the economic temperature to the comfortable one
Activating this function will ensure that when the programmed change of the set temperature resulting from
the schedule occurs, the current temperature in the room will be close to the desired value.
CAUTION
The optimum start function only works in the heating mode.
Room temperature
–
OPTIMUM START function OFF
Room temperature
–
OPTIMUM START function ON