IMPORTANT SAFETY INSTRUCTIONS.

READ AND SAVE THESE INSTRUCTIONS.

HEED ALL WARNINGS.

This unit is powered by potentially hazardous voltage. Therefore,

observe the following safety precautions:

1.

Read and follow all instructions before using product.

2.

Do not use product near water (such as near a bathtub, washbowl, kitchen sink,

swimming pool, in a wet basement, etc.).

3.

Unit should be located so that its location or position does not impede the flow of

air through the ventilation openings.

4.

Product should be located away from heat

sources such as radiators, heat registers, or other

products, including amplifiers, that produce heat.

5.

Product should be connected to a power

supply only of the type described in the oper-

ating instructions or as marked on the product.

6.

Protect power cord from being walked on

or pinched particularly at plugs, convenience

receptacles, and the point where they exit

from the unit.

7.

Do not allow objects or liquids to penetrate

the enclosure through openings.

8.

During heavy use, chassis may get hot to

the touch. Handle with care.

9.

Protect unit from strong impact.

10.

Unplug product before cleaning. Never spray liquid cleaners into the amp: wipe

with a clean, lint-free cloth to remove dirt and film.

11.

Only use attachments/accessories specified by the manufacturer. 

12.

This product should be used only with a cart or stand recom-

mended by the manufacturer. When a cart is used, use caution when

moving the cart/product combination to avoid injury from tipping over. 

13.

Amplifiers may be capable of producing high volume levels that

could cause permanent hearing loss or damage, if the exposure to

such levels is prolonged. Such damage is progressive and irreversible! If you experi-

ence any hearing loss or ringing in the ears, consult an audiologist. 

2

1

RISK OF ELECTRICAL SHOCK

DO NOT OPEN

CAUTION

CAUTION:  TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO

NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

RISQUE D'ELECTROCUTION

NE PAS OUVRIR

ATTENTION

ATTENTION:  POUR REDUIRE LES RISQUES D'ELECTROCUTION

NE PAS ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE

N'EST REPARABLE PAR L'UTILISATEUR. POUR TOUTE

REPARATION, S'ADRESSER A UN TECHNICIEN QUALIFIE.

ELEKTRISCHE SCHLAGGEFAHR

NICHT OFFNEN

VORSICHT

VORSICHT:  ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGE-

FAHR NICHT DEN DECKEL ABNEHMEN. INTERNE TEILE KONNEN

NICHT VOM BENUTZER GEWARTET WERDEN. DIE WARTUNG

IST QUALIFIZIERTEM WARTUNGSPERSONAL ZU UBERLASSEN.

This symbol, wherever it appears, alerts the user to the presence of uninsulated dangerous
voltage within the product’s enclosure that may be of sufficient magnitude to constitute a
risk of electric shock to persons.

This symbol, wherever it appears, alerts the user to important operating and maintenance
instructions in the accompanying literature. Read the manual.

14.

Unplug unit during lightning storms or when unused for long periods of

time.

15.

This unit must be earth grounded. To reduce the risk of electric shock, NEVER

remove or otherwise attempt to defeat the ground pin of the power cord. If the provid-

ed plug does not fit into your outlet, consult an electrician for replacement of the

obsolete outlet.

WARNING:

To avoid the risk of fire, electric shock or injury, do not expose this unit

to rain or moisture. Do not remove the chassis from its cabinet, or remove metal cov-

ering from chassis parts. Removing the chassis from its cabinet exposes extremely

dangerous high voltages. There are no user-serviceable parts inside. Hazardous volt-

ages are present inside the chassis. Refer all servicing to qualified personnel.

CAUTION:

Never modify the power cord. If original power cord becomes damaged,

frayed, or has exposed wires, replace immediately with same rating and gauge, or

higher. Replacements are commercially available or you can contact Tech 21 directly.

WARNING:

Attempting to repair this unit is not recommended and may void its 

warranty. NOTE: In the U.S. and Canada, servicing is performed at factory only. In

other countries, please refer repairs to the local Tech 21 authorized distributor.

FUSE

Fuse holder is located inside A/C cord receptacle. 

You must unplug 

and remove power cord to change fuse.

Replace with similar type

and same value: 100V units: use F 1A L

117V units: use F 1A L

230V units: use F 0.5A L

240V units: use F 0.5A L

QUICK START AND STOP INSTRUCTIONS

QUICK START:

Here’s how you can get your Trademark 30 up and running before

you read the entire manual. Note: By not reading the manual, you’ll miss out on how

to get the most out of your new investment! 

1.  Plug your instrument into the top-panel Input jack (on the left side).

2.  Attach the AC cord to the amp and plug into a wall socket.  

3.  Be sure the Level controls on the Trademark 30 are down, then turn on the amp. 

4.  Use the quick start sample settings provided on the amp. If missing, please refer

to the Sample Settings in this manual. 

5.  Play your guitar and you should hear a sound coming through the amp. If not, check

that your guitar’s volume control is turned up, recheck your connections, and be sure your

cable isn’t faulty. If there is still no sound, refer to factory or qualified technician.

QUICK STOP:

After shutting off the Trademark 30 (or any amp), 

wait at least 10 seconds

before turning it back on.

Summary of Contents for Trademark 30

Page 1: ...arranty period expires manufacturer will repair defective unit for a fee PROOF OF PURCHASE IS REQUIRED FOR ANY REPAIR For residents of the U S and Canada please call Tech 21 s main headquarters for sh...

Page 2: ...nce of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol wherever it appears alerts the use...

Page 3: ...acclaimed SansAmp pioneered Tube Amplifier Emulation in professional applications for recording direct and performing live and created an entirely new category of signal processing While there have s...

Page 4: ...clock and a slight High boost 2 o clock 5 REVERB Rich full sounding Accutronics 3 spring reverb Increase from minimum 7 o clock We recommend starting at 12 o clock and then adjusting to taste LEVEL A...

Page 5: ...lifted If neces sary connect the ground by pushing the button in 7 EFFECT LOOP The Effect Loop allows you to connect external effects between the pre amp and power amp section of the Trademark 30 Conn...

Page 6: ...95UF or equivalent When available it is preferable to use XLR jacks TRADEMARK 30 STEREO HOOK UP with POWER ENGINE 60s SEND RETURN TRADEMARK 30 TRADEMARK 30 INPUT CHAINING TRADEMARK 30s SANSAMP XLR DIR...

Page 7: ...SAMPLE SETTINGS MESA BOOGIE LEAD METALLICA JAZZ SRV VAN HALEN STRAT LES PAUL CLEAN RHYTHM AC DC CUSTOM SETTINGS...

Page 8: ...l x 8 w x 13 25 h Weight 14 lbs Measured using a 10dB 400Hz test signal with all amp controls flat no reverb Actual levels will vary with your settings Optional Accessories and Speaker Cabinets Gig Ba...