background image

15

Removing the toilet lid

 

ƒ

Lift up the toilet lid and toilet seat.

 

ƒ

Remove both set screws from the hinges (D) using an Allen key (2.5 mm).

 

ƒ

Hold the toilet lid and seat with both hands and pull them gently upwards.

Note: During assembly, after mounting both hinges, press down on the attach-

ment bolts – at the same time, applying slight pressure – until they audibly click 

into place.

Replacing the shower nozzles

The scope of delivery includes three shower nozzles (standard 75°). To replace 

them, proceed as follows:

 

ƒ

Turn the water flow regulator until the shower arm extends a little.

 

ƒ

Pull out the shower arm with your hand and turn off the water supply (G).

 

ƒ

Hold the shower arm firmly with one hand and with the other, pull the nozzle 

forwards until it comes off the shower arm (H).

 

ƒ

Then push your chosen shower nozzle – with the opening pointing upwards 

– onto the shower arm until it gently locks into position.

As an option, additional shower nozzles can be ordered which differ from each 

other in terms of the intensity and position of the shower spray (see “Spare 
parts” section).

EN

Summary of Contents for TECEone

Page 1: ...so Gebruiksaanwijzing Instrukcja obs ugi Bruksanvisning Bruksanvisning Upute za uporabu N vod k obsluze Kasutusjuhend Lieto anas instrukcija Naudojimo instrukcija Instruc iuni de utilizare Kullan m k...

Page 2: ...2 A C B G E F H D...

Page 3: ...14 Testing the temperature of the water when using for the first time 14 Starting the shower function 14 Removing the toilet lid 15 Replacing the shower nozzles 15 4 Cleaning and maintenance 16 Lid a...

Page 4: ...use The TECEone is a wall mounted toilet ceramic with a shower function intended for intimate personal cleansing with water in a closed room It can also be used as an ordinary toilet ceramic without...

Page 5: ...able level factory setting is 38 C If the tempera ture is clearly too high the temperature must be reset by a qualified special ist Turn the temperature regulator to the required temperature or to the...

Page 6: ...es three shower nozzles standard 75 To replace them proceed as follows Turn the water flow regulator until the shower arm extends a little Pull out the shower arm with your hand and turn off the water...

Page 7: ...when using a cleaning product Avoid any contact with hard or metal objects which could damage or mark the surface Shower arm Slightly turn the water flow regulator A to self cleaning The shower arm do...

Page 8: ...le does not extend The water pressure is too low Call the fitter The shower jet is too weak The water supply hose is bent Call the fitter The shower nozzle or shower arm is blocked cal cified Clean th...

Page 9: ...pressure min 1 bar 0 1 MPa max 10 bar 1 MPa Water consumption up to 5 l min 7 Spare parts 9820361 9820366 9820367 9820403 3 x standard 75 9820404 3 x standard 90 9820405 3 x medium 90 9820406 3 x sma...