InstallatIon
General information
4 |
sK 2
1. General information
this document is intended for contractors.
Note
Read these instructions carefully before using the ap-
pliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1 Relevant documents
Heat pump operating and installation instructions
Note
Please see appliance operating and installation in-
structions for information on the "Guarantee" and
"Environment and recycling".
1.2 Units of measurement
Note
all measurements are given in mm unless stated oth-
erwise.
2. Appliance description
Dimensions
450
303
50
410
D
00000
69
18
6
2.1 Standard delivery
- 4 screws M8x30
- 4 washers
3. Preparations
3.1 Foundation
B
C
A
1
3
2
150
150
D
00000
63
48
6
1 air intake side
2 air discharge side
3 Main wind direction
Heat pump
A
B
C
3 Cs Plus, 3.5 aCs,
07 aCs classic
850
500
408
4 Cs Plus, 4.5 aCs,
09 aCs classic
850
500
408
6 Cs Plus, 6.5 aCs,
13 aCs classic
980
500
408
8 Cs Plus, 8.5 aCs,
17 aCs classic
980
500
408
f
f
Erect a strip foundation at the heat pump installation site.
3.2 Gravel bed
>800
100
a
D
00000
69
29
4
1
1 Drainage pipe
Heat pump
a
3 Cs Plus, 3.5 aCs,
07 aCs classic
700
4 Cs Plus, 4.5 aCs,
09 aCs classic
700
6 Cs Plus, 6.5 aCs,
13 aCs classic
830
8 Cs Plus, 8.5 aCs,
17 aCs classic
830
f
f
lay a drainage pipe under the appliance to drain moisture
away from the building.
InstallatIon