44 1683 001M1-D
MasterDrainer 80 Kombi
25
Suction extraction using the compressed air supply: Connect the
compressed air supply and open the ball valve on the ejector
Start the suction extraction process by opening the ball valve on the
suction hose
To end the suction extraction process close the ball valve on the suction
hose again
Suction extraction with disconnected compressed air supply Close the ball
valve on the ejector and disconnect the air supply
To end the suction extraction process close the ball valve on the suction
hose again
3.3.3.
Suction output
The suction output of the equipment is dependent on the properties of the
medium and the selected suction probe.
The oil is to be extracted as far as possible at operating temperature
(max. 50° C).
The suction probe (adapter) is to be selected with the largest possible
cross section.
Keep the suction hose as far as possible straight and without tight bends
or buckled.
The diagram
presents target
values for the
suction output.