44 1268 102-G
HORNET 40
7
3.
Assembly instructions
Fit suction filter (1) to suction pipe (2)
and secure by means of light hose
clamp (3). Slip transparent suction
hose (4) approx. 30 mm on the suction
pipe (2). Cut the delivery hose to
required length and slide it on to the
suction pipe socket (5) of the priming
pump (14). Tighten both hose clamps
(8) on the hose (6). Slip hose on
pressure connection (9) of the pump.
Slip angular wire end of anti-knik
spring under the hose clamp. Tighten
hose clamp (8). Fit nozzle ZP19 to
other end of pressure hose (23) using
the hose clamp.
The Hornet 40 Automatic is designed
with an automatic nozzle valve A2010
instead of the nozzle ZP19. For that
purpose fit supplied hose union (21)
with clamp (8). Plug thread (21) on
nozzle and tighten.
Tight pump into opening of tank, thus
considering that the pump can only be
placed and operated in a vertical
position.
By twisting the motor casing (11) the
pump outlet can be put into the
wanted position.
Connect power supply.
For type Hornet G40 a direct currency
socket is required according to DIN
72591 C or D.
The circuit cross section of the plug
supply line at direct currency
operation should amount to 2,5 qmm
thus avoiding large voltage drop.
3.1.
Requirements for the location of installation.
Since the media handled by the pump are harmful to water, the HORNET pump must
be positioned, maintained and operated such that contamination of water or other
significant modification of its properties is avoided. The relevant local legislation
must be complied with.