background image

44 1268 102-G     

HORNET 40 

3.

 

Assembly instructions  

 
Fit suction filter (1) to suction pipe (2) 
and secure by means of light hose 
clamp (3). Slip transparent suction 
hose (4) approx. 30 mm on the suction 
pipe (2). Cut the delivery hose to 
required length and slide it on to the 
suction pipe socket (5) of the priming 
pump (14). Tighten both hose clamps 
(8) on the hose (6). Slip hose on 
pressure connection (9) of the pump. 
Slip angular wire end of anti-knik 
spring under the hose clamp. Tighten 
hose clamp (8). Fit nozzle ZP19 to 
other end of pressure hose (23) using 
the hose clamp.   
 
The Hornet 40 Automatic is designed 
with an automatic nozzle valve A2010 
instead of the nozzle ZP19. For that 
purpose fit supplied hose union (21) 
with clamp (8). Plug thread (21) on 
nozzle and tighten. 
Tight pump into opening of tank, thus 
considering that the pump can only be 
placed and operated in a vertical 
position. 
By twisting the motor casing (11) the 
pump outlet can be put into the 
wanted position. 
Connect power supply. 
For type Hornet G40 a direct currency 
socket is required according to DIN 
72591 C or D. 
The circuit cross section of the plug 
supply line at direct currency 
operation should amount to 2,5 qmm 
thus avoiding large voltage drop.  
 
 

3.1.

 

Requirements for the location of installation.  

Since the media handled by the pump are harmful to water, the HORNET pump must 
be positioned, maintained and operated such that contamination of water or other 
significant modification of its properties is avoided. The relevant local legislation 
must be complied with. 

Model HORNET40 Standard 

Model HORNET40 Automatic 

21 

22 

13 

12 

16 

17 

11 

15 

14 

23 

Summary of Contents for HORNET 104428700

Page 1: ...nual GB Operating manual HORNET W 40 G 40 12 G 40 24 Item No 104458475 104428700 104438700 104448700 104458475 104458702 104468702 104468722 104478702 104478722 104528700 104538700 104548700 104558702...

Page 2: ...cient knowledge of the operating manual Copyright HORN GmbH Co KG All rights reserved Text graphics and layout copyright protected Reproduction and copying including in part only permitted with writte...

Page 3: ...ormation Specific details on the economic use of the device Specific details and or instructions for damage prevention Details and or instructions for preventing injury to persons or extensive materia...

Page 4: ...ling oils greases fuels and other chemical substances Water protection The device has been constructed for use with water contaminants It is to be operated such that bodies of water cannot be polluted...

Page 5: ...in case of power failure The automatic self closing nozzle A2010 closes perfectly when the tank to be filled is full when the nozzle is held in a vertical position or when the nozzle falls to the gro...

Page 6: ...10 104 568 702 HORNET G 40 12 A FMT 3 FMT 3 Automatic nozzles A 2010 104 568 722 HORNET G 40 12 A FMT 3 FMT 3 Automatic nozzles A 2010 104 578 702 HORNET G 40 24 A FMT 3 FMT 3 Automatic nozzles A 2010...

Page 7: ...Plug thread 21 on nozzle and tighten Tight pump into opening of tank thus considering that the pump can only be placed and operated in a vertical position By twisting the motor casing 11 the pump outl...

Page 8: ...6 may not be left lying on the ground in order to avoid damages to the hose 4 2 1 Normal operation of type with nozzle ZP 19 a Switch on electric pump b Hold nozzle into filling container and or put n...

Page 9: ...d the feeler jet 17 which is situated in the outlet has not been contaminated and the flow volume is not less than 12 l min 5 Demontage In case the pump has to be dismounted from barrel or container 1...

Page 10: ...egulations are to be followed 7 1 Return of batteries Batteries must not be disposed of with the domestic waste Batteries can be returned free of charge via a suitable collecting point or to the dispa...

Page 11: ...44 1268 102 G HORNET 40 11 8 Declaration of conformity...

Page 12: ...12 44 1268 102 G HORNET 40 HORN GmbH Co KG Munketoft 42 24937 Flensburg Germany T 49 461 8696 0 F 49 461 8696 66 www tecalemit de info tecalemit de...

Reviews: