background image

TECA

1-888-TECA-USA (832-2872)

www.teca-usa.com

AHP-250 Air Conditioner

Air Cooled

12 VDC, 24 VDC

Through Mounted

129 BTU/HR

Nema-12, 4, 4X

FEATURES

• Compact (only 6” X 4.75” X 6.6”)

• Mounts and operates in any orientation:

horizontal, vertical, etc.

• Low vibration and noise

• No moving parts except fans

• Environmentally safe

• No compressor, fluorocarbons or filters

• Heat via reverse polarity

• Virtually maintenance-free operation

• Weight  4.4 LBS.

Operating Ambient

-40/+70 °C

Operating Enclosure

-10/+60 °C

OPERATING TEMPERATURES

INCLUDES

• Mounting gasket

• Mounting hardware

• Power input leads

Cooling (Traditional)

129 BTU/HR

Cooling (Din 3168)

38  WATTS

Cooling COP (at L35 L35)

0.53

PERFORMANCE RATINGS

OPTIONS

• Temperature Control TC-6F DC for cool only

• Temperature Control TC-3F DC for heat/cool

• Adaptable for TC-3400

• Stainless steel exterior housing

CONFIGURATIONS

MODEL

PART NUMBER

NOTES

HEAT

VOLTAGE

CURRENT

ENVIRONMENT

Watts

VDC

AMPS

AHP-250FF

0-L094-1-000

Industrial Fans

100

12

6

NEMA-12, IP 52

AHP-250FF

0-L095-1-000

Industrial Fans

100

24

3

NEMA-12, IP 52

AHP-250XE

0-L094-5-000

Sealed Hot Side Fan

100

12

6

NEMA-4, IP 56

AHP-250XE

0-L095-5-000

Sealed Hot Side Fan

100

24

3

NEMA-4, IP 56

AHP-250X

0-L094-3-000

Mil. Grade Hot Side Fan

100

12

6

NEMA-4X, IP 56

AHP-250X

0-L095-3-000

Mil. Grade Hot Side Fan

100

24

3

NEMA-4X, IP 56

Heat function via reverse polarity (controller dependent)

AC.qxp  4/22/2014  3:09 PM  Page 78

Summary of Contents for 0-L094-1-000

Page 1: ...fully before installation Only qualified technicians should install this equipment If you have any questions regarding your equipment please do not hesitate to call us at 773 342 4900 and we will be happy to assist you We are open from 8 00 am 4 30 pm Central Time Included in this packet you will find Installation Notes for Air Conditioners Product Literature and Specifications Assembly Drawing SK...

Page 2: ...ften the most difficult to protect from condensation in this orientation due to the fin orientation gravity and any susceptible components below If a drip pan is employed by the end user use caution to place the pan far enough away from the internal fan to minimize the restriction of air flow The pan should cover the fin ends as well as the fan area When there is a choice the vertical orientation ...

Page 3: ... HR Cooling Din 3168 38 WATTS Cooling COP at L35 L35 0 53 PERFORMANCE RATINGS OPTIONS Temperature Control TC 6F DC for cool only Temperature Control TC 3F DC for heat cool Adaptable for TC 3400 Stainless steel exterior housing CONFIGURATIONS MODEL PART NUMBER NOTES HEAT VOLTAGE CURRENT ENVIRONMENT Watts VDC AMPS AHP 250FF 0 L094 1 000 Industrial Fans 100 12 6 NEMA 12 IP 52 AHP 250FF 0 L095 1 000 I...

Page 4: ...r y 1 35x 51 y 1 34x 52 Cold Sink y 1 15x 51 7 y 1 13x 52 6 AHP 250 Air Conditioner Air Cooled MOUNTING STYLE Through Mounted ENVIRONMENTS SERVED NEMA 12 IP 52 NEMA 4 4X IP 56 RATING TRADITIONAL 129 BTU hr 0 F T 162 BTU hr 20 F T RATING DIN 3168 38 Watts L35 L35 28 Watts L35 L50 DIMENSIONS Air Flow Pattern AC qxp 4 22 2014 3 09 PM Page 79 ...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ...ree of charge to Buyer or credit to buyer the price of the defective products ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL INDIRECT INCIDENTAL CONSEQUE...