MODEL

PART

NOTES

TEMP @

TEMP @

T1-T2

RESET

RESET

TEMP @ T3

OPERATING

SWITCHING

SWITCHING

NUMBER

NUMBER

T1 

°

C

T2 

°

C

(MAX) 

°

C

(TYP) 

°

C

°

C

VOLTAGE

VOLTAGE

CURRENT

TC-6F

6F-00A-00-000

No Relay

35 +/- 5

25 +/- 5

10 +/- 3

6.5

3

Continuous On

NA

NA

NA

TC-6F-AC

6F-03T-00-000

VAC Version

35 +/- 5

25 +/- 5

10 +/- 3

6.5

3

Continuous On

85-250 VAC

24-280 VAC

10 

TC-6F-DC

6F-43D-00-000

12/24 VDC

35 +/- 5

25 +/- 5

10 +/- 3

6.5

3

Continuous On

12/24 VDC

0-100 VDC

.02-20 ADC

TC-6F-DC

6F-33D-00-000

48 VDC

35 +/- 5

25 +/- 5

10 +/- 3

6.5

3

Continuous On

48 VDC

0-100 VDC

.02-20 ADC

MODEL

PART

NOTES

COOL

HEAT

RESET

RESET

OPERATING

SWITCHING

SWITCHING

NUMBER

NUMBER

TEMP.

°

C

TEMP.

°

C

(MAX) 

°

C

(TYP) 

°

C

VOLTAGE

VOLTAGE

CURRENT

TC-3F-AC

3F-04R-00-000

VAC Version

35 +/- 5

15 +/- 5

6.5

3

85-280 VAC

24-280 VAC

10 AMPS

TC-3F-DC

3F-44G-00-000

12/24 VDC

35 +/- 5

15 +/- 5

6.5

3

3.5-32 VDC

0-100 VDC

.02 - 20 ADC

TC-3F-DC* 3F-44P-00-000

12/24 VDC

35 +/- 5

15 +/- 5

6.5

3

3.5-32 VDC

0-100 VDC

.02 - 20 ADC

* H-Bridge relays included

Model TC-6F (Cool Only) thermostat is designed using two temperature power switches in conjunction with a solid state relay. A three position
switch is provided to adjust temperature settings.

Model TC-3F (Heat/Cool) thermostat incorporates the same technology as the TC-6F. It contains a single setting each for both heating and 
cooling as referenced below:

TC-1F POWER TEMPERATURE SWITCHES

Models TC-1F power temperature controller, with small tolerance and reset differential, are
the simplest and most cost effective way to control a cooling or heating device (VAC or VDC)
without a need for a relay. For circuits that have higher current draw simply use them in
conjunction with a solid state relay.

TC-6F COOL ONLY

TC-3F HEAT AND COOL

Part Numbers:

Mode

Part Number

Note

Cool  

TC-1C-

XX

switch closes on temperature rise

Heat  

TC-1H-

XX

switch closes on temperature drop

XX:

Specify temperatures 20 °C, 25 °C, 30 °C, 35 °C for cool mode   

and 10°C, 15 °C  for heat mode

Example: TC-1C-20 and TC-1H-10

VOLTAGE

CURRENT

SET POINT T

RESET

AMPS

OLERANCE 

°

C

DIFFERENTIAL 

°

C

125 VAC

2

+/- 3

3 - 6

250 VAC

1.3

+/- 3

3 - 6

12 VDC

2

+/- 3

3 - 6

24 VDC

1.3

+/- 3

3 - 6

Dimensions: Inches [Millimeters]

MODEL

PART

NOTES

COOL

HX

HEAT

RESET

RESET

OPERATING

SWITCHING

SWITCHING

NUMBER

NUMBER

TEMP.

°

C

TEMP.

°

C

TEMP.

°

C

(MAX) 

°

C

(TYP) 

°

C

VOLTAGE

VOLTAGE

CURRENT

TC-7F-DC

7F-24G-00-000

24 VDC

35 +/- 3

25 +/- 3

10 +/- 3

6.5

3

24 VDC

24 VDC

.02 - 20 ADC

H-Bridge relays included

Model TC-7F (Heat/Cool) thermostat incorporates the same technology as the TC-3F. It contains a single setting each for both heating and 
cooling and a heat exchanger mode (ECO-Mode).

TC-7F HEAT/COOL WITH ECO-MODE

TC-4F COOL ONLY WITH ECO-MODE

Model TC-4F is simillar to TC-1F plus it has a 2nd power switch for heat exchanger mode (ECO-Mode). The active cool set point for TC-4F is 35 

°

C

and for heat exchanger mode (ECO-Mode) is 25 

°

C

.

MODEL

PART

NOTES

HX

COOL

RESET

RESET

OPERATING

SWITCHING

ACTIVE MODE

ECO-MODE

NUMBER

NUMBER

TEMP.

°

C

TEMP.

°

C

(MAX) 

°

C

(TYP) 

°

C

VOLTAGE

VOLTAGE

SWITCHING

SWITCHING

CURRENT

CURRENT

TC-4F-DC

4F-24G-00-000

24 VDC

25 +/- 3

35 +/- 3

6.5

3

24 VDC

24 VDC

.02 - 20 ADC

1.3 ADC

For custom variations of any of the controls, contact TECA.

Catalog 2012 AC.qxp  10/24/2012  2:21 PM  Page 110

Summary of Contents for 0-0135-1-000

Page 1: ...efully before installation Only qualified technicians should install this equipment If you have any questions regarding your equipment please do not hesitate to call us at 773 342 4900 and we will be...

Page 2: ...is often the most difficult to protect from condensation in this orientation due to the fin orientation gravity and any susceptible components below If a drip pan is employed by the end user use caut...

Page 3: ...n Integral temperature controller Operating ambient temperature range 40 65 C Operating enclosure temperature range 10 60 C Weight 55 LBS CONTROL TEMPERATURES INCLUDES Temperature controller Mounting...

Page 4: ...YLE Through Mounted ENVIRONMENTS SERVED NEMA 12 IP 52 NEMA 4 4X IP 56 RATING TRADITIONAL 1100 BTU hr 0 F T 1420 BTU hr 20 F T RATING DIN 3168 322 Watts L35 L35 210 Watts L35 L50 AHP 1800 DIMENSIONS Ai...

Page 5: ......

Page 6: ...H S FAN H S FAN TE TE TE C S FAN 1 2 TE TE TE TE TE TE 1 2 6 4 3 5 7 8 6 5 4 3 8 7 250 VDC Input TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE 13469 10 F 1N4148 C S FAN...

Page 7: ...re utilis par des personnes enfants compris dont les capacit s physiques sensorielles ou mentales ou le manque d exp rience et de connaissances moins qu ils aient t donn s de surveillance ou d instruc...

Page 8: ...d most cost effective way to control a cooling or heating device VAC or VDC without a need for a relay For circuits that have higher current draw simply use them in conjunction with a solid state rela...

Page 9: ...ee of charge to Buyer or credit to buyer the price of the defective products ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY...

Reviews: