FanControl‑GSM v2
10
Menu
Menu
code
Factory
default Note
Climatic system settings
***
26
1
1 — Activation immediately after a heater is
turned on
2 — Delayed activation after a heater is turned on
3 — Activation by temperature
4 — Activation after a delay or by temperature
(depending on what comes first)
5 — Climatic system inactive
Delay before Climatic
system activation
***
28
2
1 – 5 min; 2 – 10 min; 3 – 15 min; 4 — 20 min;
5 — 25 min; 6 — 30 min
Engine temperature
for climate system
activation
***
30
2
1 — 30°C; 2 — 40°C; 3 — 50°C; 4 — 60°C;
5 — 70°C; 6 — 80°C
Output settings № 11
36
1
1 — Heater operational status. A constant level
of electrical signal is formed while a heater is in
operation (If it is activated with FanControl).
2 — Control of recirculating pump. A constant
level of electrical signal is formed while a heater
is in operation and also within 2 minutes after a
heater is deactivated. The signal would be formed
if the heater was activated with FanControl.
3 — Ventilation status. A constant level of
electrical signal is formed while ventilation is in
operation (If it is activated with FanCocntrol).
4 — Reserved by the manufacturer.
Output settings № 23
38
*
Used only in special cases. Check documentation to see which vehicles require these settings (www.tecel.ru\en\).
**
Sensor is installed if there is no data in the CAN‑bus.
***
Engine temperature for climate system activation.
Programming sequence
1.
Choose required option in table 5. Then press PB amount of times corresponding to menu
code. LED will inform you about it’s state.
2.
Change option state. To do so press PB required amount of times, required to change the
option value to the chosen one. Mind that the first value, goes after last value.
System will leave programming mode and save all changes after turning off the ignition or after
15 seconds after last button press. LED will flash 4 times if settings were saved succesfully or 1
time if there was an error during save.
Factory settings reset
You may reset system settings to factory defaults.
To do so:
1.
Disconnect system from power and CAN‑bus.
2.
Press and hold PB.
3.
While holding PB, supply power to the system (CAN‑bus should be disconnected). Wait for
LED flashes.
4.
Turn off the power, release PB.
Table 6. Technical data
Characteristic
Value
Power, V
9 ... 15
Maximum current draw in operation mode, mA
500
Maximum current draw in rest mode, mA
10
Temperature,
°
C
–40 ... +85
Maximum relative humidity, %
95