background image

8

Programming sequence

1  Turn the ignition on.

Enter the PIN code and wait for confirmation.

3  Enter Menu 1 by pressing and releasing the Programming but-

ton 10 times (you need to do this no later than 10 seconds 

upon PIN code entering). The Immobilizer will notify of menu 

accessed by three sound trills.

4  Select menu option by pressing and releasing the Programming 

button for the number of times corresponding with the menu 

option number. The Immobilizer will inform on menu number 

by series of audible signals.

5  Go to option setting by pressing and holding the brake pedal. 

The Immobilizer will inform you on the option setting by series 

of audible signals, and their duration will change.

6  Change the option setting by pressing and releasing the Pro-

gramming button for the number of times necessary for moving 

from the current setting number to the required setting number 

in the option (e.g., in order to change function No. 2 (Lock Im-

pulse) with function No. 16 (External lights) you need to press 

and release the programming button 14 times. The Immobilizer 

will inform on the new option setting with series of audible sig-

nals. It is necessary to consider that during navigation in the op-

tion the first number goes after the last one. Release the brake 

pedal; the Immobilizer will indicate the current setting and then 

the current menu option number. Now you can proceed with 

programming the next option and leave the programming mode.
6.1 6.1. Function No. 7 Doors, hood and trunk programming al-

gorithm (applicable only for options No. 7 and 8 of Menu 1).

6.1.1  Set any combination of doors, hood and trunk, the open-

ing of which will cause the Immobilizer to form a signal 

on the programmable output. For the purposes of this descrip-

tion doors, hood and trunk are simple referred to as doors.
6.1.2  With the brake pedal pressed go to option number 7 

settings. Immobilizer will inform on option condition twice 

with series of 7 audible signals, after which it will start 

emitting irregular audible signals. When you hear irregular 

audible signals, release the brake pedal. The Immobilizer will 

continue emitting irregular audible signals. Open the doors 

that are to be identified on this output, the rest are to be 

closed (you can open the doors in advance). Press the brake 

pedal again. Immobilizer will inform on option setting change 

with series of 7 signals and the doors will be assigned to this 

output. If the brake pedal is not pressed and current option 

programming is left, the Immobilizer will save its previous 

condition. Release the brake pedal and the Immobilizer will 

go to option number indication.

6.2 Function No. 8 Original button programming algorithm (ap-

plicable only for options No. 7, 8 of Menu 1).

6.2.1  With the brake pedal pressed go to option number 8 

settings. Immobilizer will inform on option condition twice with 

series of 8 audible signals, after which it will start emitting 

irregular audible signals. When you hear irregular audible sig-

nals, press the required button while holding the brake pedal 

(for the list of buttons of the given model, please see Integra-

tor files). If the Immobilizer has perceived the button, it will 

stop emitting irregular audible signals and will start indicating 

the option setting number with series of 8 audible signals. 

Release the brake pedal, the Immobilizer will indicate menu 

option number. If the brake pedal is released prior to the but-

ton is pressed, the Immobilizer will save its previous condition 

and will start indicating the menu option number

6.3 

Function No. 9 Transmission condition programming algo

-

rithm (applicable only for options No. 7, 8 of Menu 1).

6.3.1 

With the brake pedal pressed go to option number 9 

settings. Immobilizer will inform on option condition twice with 

series of 9 audible signals, after which it will start emitting ir

-

regular audible signals. When you hear irregular audible signals, 

change the transmission to the required position: P, N, D

*

 or R 

(transmission handle can be set in the necessary position in ad-

vance); for robotized transmission the positions are R, N, D

 

*

for manual transmission only R position is available. Release 

and press the brake pedal again. The Immobilizer will stop 

emitting irregular audible signals and will start indicating 

the option setting number with series of 9 audible signals. 

Release the brake pedal, the Immobilizer will indicate menu 

option number. If the brake pedal is released prior to the but-

ton is pressed, the Immobilizer will save its previous condition.

7  In order to go to next menu option programming press and re-

lease the Programming button for the number of times neces-

sary for navigation from the required option (e.g., in order 

to navigate from option No. 2 to option No. 8 in Menu 1 press 

and release the Programming button 6 times). Important note: 

when navigating menu options, the first option follows the last 

one.

Exiting the programming mode. The Immobilizer will exit program-

ming mode and save all configuration settings in energy independent 

memory when ignition is turned off or within 60 seconds after last 

menu action if the brake pedal is released.

— all handle positions for vehicle advancement (D, S, M, L etc.).

Table 5. CAN bus adapter functions

Function

Function description

No.

Name

1

Security

Constant level signal is formed while Immobilizer is in Security mode

2

Lock Impulse

0.8 second long impulse is formed when Immobilizer is entering the Security mode

3

Unlock Impulse

0.8 second long impulse is formed when Immobilizer is leaving the Security mode

4

Panic 1

Constant level signal is formed while the original car alarm (if the vehicle is equipped with it) is in alarm 

mode.

5

Panic 2

Perimeter security

30 seconds long constant level signal is formed if one of the following zones is triggered: doors opening, 

hood opening (if CAN bus has the corresponding data or input No. 8 is connected), trunk. The func-

tion can be applied in vehicles that are not equipped with original alarm system. The signal stops when 

vehicle is not in Security mode any longer.

6

Panic 2-K

Perimeter security with 

claxon output

30 seconds long constant level signal is formed if one of the following zones is triggered: doors opening, 

hood opening (if CAN bus contains the corresponding data or input No. 8 is connected), trunk. The func-

tion can be applied in vehicles that are not equipped with original alarm system. The signal stops when 

vehicle is not in Security mode any longer. This feature is used for sending an alert signal to the original 

vehicle claxon.

7

Doors, hood and trunk

Constant level signal is formed if one of preset doors, hood (if CAN bus contains the corresponding data 

or input No. 8 is connected) or trunk is opened.

8

Original button

Constant level signal is formed if the preset vehicle button is pressed (see Integrator files application).

9

Transmission condition

Constant level signal is formed if transmission handle is set in preliminarily programmed position (P, R, 

N, and D). For robotized transmission the positions are R, N, D; for manual transmission only R position 

is available.

10

Sensor ignoring

Constant level signal is formed when the trunk is open in Security mode if the trunk has been opened 

with the original remote control. Also the signal is formed for the purposes of Comfort function. 

The function’s purpose is to deactivate the sensors in order to prevent false alarms.

11

Ignition

Constant level signal is formed when ignition is turned on (including engine starting).

12

ACC

Constant level signal is formed when vehicle ACC are on (1st key position, may match with ignition 

on certain vehicles). It is turned off only when the ignition key is out of ignition lock. Can be used 

for correct accessory multimedia system power management.  

13

Engine on

Constant level signal is formed when the engine is on.

Summary of Contents for PRIZRAK 520

Page 1: ...520 T E C H N I C A L SPECIFICATION INTELLECTUAL S Y S T E M t h e f t p r e v e n t i o n PRIZRAK...

Page 2: ...ng and preventing the vehicle s engine from operation with help of a relay PIN and PUK codes PIN code PIN code is a secret combination of original vehicle button s press ings Please see the Integrator...

Page 3: ...on has been turned off the Immobilizer will save its current condition and will continue its operation when the ignition is back on Anti HiJack s Guard mode can be deactivated at any phase by entering...

Page 4: ...ry hood lock Output con figuration is carried out via programming see Immobilizer hardware functions programming Menu 1 1 Port connector pins enumeration from wir ing viewpoint Table 1 Immobilizer por...

Page 5: ...t Red Communication channel and power supply 12 1 10 m 1 Black Power supply Ground Violet Locking output 10 Violet Locking output 10 1 Transfer mode impulse up to 1 A Reception mode 10 mA Communicatio...

Page 6: ...econds until an audible signal will be heard Communication check between the central unit and pLine 221 relay 1 Turn the ignition on 2 Enter the PIN code and wait for confirmation 3 Press and release...

Page 7: ...l l o p t i o n s can be reprogrammed 3 User prohibition is set for all the options aside from 1 Pass word needs to be entered in order to remove prohibition see below 4 Admin prohibition is set for a...

Page 8: ...ch it will start emitting ir regular audible signals When you hear irregular audible signals change the transmission to the required position P N D or R transmission handle can be set in the necessary...

Page 9: ...rake pedal pressings 3 From 1 to 7 5 Anti HiJack feature response delay 1 From 1 to 10 6 PIN code entering audio confirmation On 1 2 7 Maintenance mode audio indication On 1 2 8 Central locking when d...

Page 10: ...s 5 Enter option No 3 by pressing and holding the brake pedal The Immobilizer will inform you on the option setting by repeated double audible signals because the current factory set option setting is...

Page 11: ...ess with port 1 Compact disc 1 Connection scheme 1 User manual 1 Warranty certificate 1 Reminder card 1 Packaging 1 Technical characteristics Parameter Value Power supply voltage V 9 15 Maximum curren...

Page 12: ...factured by TEC Electronics Ltd The product is manufactured in accordance with TC 4372 008 78025716 11 Certificate of conformity No POCC RU AB75 B00423 The product corresponds with the requirements of...

Reviews: