Inverter pump

Pool heat pump

User manual

Summary of Contents for INVERTER S

Page 1: ...Inverter pump Pool heat pump User manual...

Page 2: ...5 Assemblyconditions 5 Hydraulic connections 6 Electrical connections 6 Priority of the heating process 7 Use 8 Waterconnection 8 Regulation digitalcontroller 9 Setting the water flow 12 Settingsforth...

Page 3: ...ending the carrier by registered mail the details of the damage This heat pump is designed and intended for use in private swimming pools only Tebas is not responsible for the use of the pump in other...

Page 4: ...ose hazards related to Electrically controlled components Moving parts automatically started fan Sharp edges evaporator To avoid accidents keep children and pets away from the device Do not cover the...

Page 5: ...e unit evaporator air inlet and a minimum of 3 m 120 in on the exhaust side of the fan It must be ensured that the removed air is not drawn back into the evaporator Sufficient space must be maintained...

Page 6: ...t pipe must be connected to the connection marked with the symbol The water discharge pipe must be connected to the connection marked with the symbol The water pipes must be fixed to the floor or wall...

Page 7: ...K PXVW EH VHSDUDWHG ZLWK D PLQLPXP GLVWDQFH RI FP LQFKHV EHWZHHQ WKHP 7KH KHDW SXPS V SRZHU VXSSO PXVW EH V VWHP SURWHFWHG LQ DFFRUGDQFH ZLWK ORFDO UHJXODWLRQV 3ULRULW RI WKH KHDWLQJ SURFHVV W LV SRVV...

Page 8: ...30 C 50 F and 86 F The device can then be started Whenever the pool heat pump is started up especially at the start of the bathing season the following procedure must be followed in the order given O...

Page 9: ...ise level speed low The device heats the water to the desired temperature 1 C Intelligent heating mode the device regulates its own power ensuring the highest efficiency The device heats the water to...

Page 10: ...sage SET and the desired water temperature Adjust the desired value with the button or button and wait a few seconds until it is automatically saved Work messages The three symbols in the lower left c...

Page 11: ...AL10 AL11 Heat pump error AL15 AL16 Temperature difference between water inlet and outlet too great AL18 Compressor outlet temperature difference too high AL17 Low temperature protection in cooling mo...

Page 12: ...C 20 C 12 C the bypass is set correctly between 10 and 15 C Pressure abnormal If the pressure is too high or too low this indicates the wrong water flow in the heat pump The flow must then be adjuste...

Page 13: ...to wind and sun the pool surroundings and the size of the heat pump Maintaining the temperature After reaching the set temperature the filtration time can be shortened according to the temperature req...

Page 14: ...ass valves Please contact the seller and provide him with the information listed including pool dimensions contact details address telephone number and a description of the problem After providing all...