![TEAMWELDER MMA 300 CEL Operating Instructions Manual Download Page 34](http://html.mh-extra.com/html/teamwelder/mma-300-cel/mma-300-cel_operating-instructions-manual_828617034.webp)
Design and function
Advanced settings
34
299-010300-TWD01
21.09.2015
5.9
Advanced settings
To enable the greatest possible breadth of applications, the following parameters can be adjusted
or optimised for the welding task.
5.9.1
Arc length restriction (USP)
EXIT
ENTER
2 s
2 s
Figure 5-14
Display
Setting/selection
Arc length restriction
on
Function switched on (TIG, factory setting)
off
Function switched off (MMA, factory setting)