Machine description
– quick overview
Machine control
– Operating elements
299-010300-TWD01
21.09.2015
17
4.3
Machine control
– Operating elements
Figure 4-3
Item Symbol
Description
0
1
Collective interference signal light
For error messages, - See 7 Rectifying faults chapter
2
Excess temperature signal light
In case of excess temperature, temperature monitors de-activate the power unit, and
the excess temperature control lamp comes on. Once the machine has cooled down,
welding can continue without any further measures.
3
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
4
Switch display button
AMP
Welding current display
VOLT
Welding voltage display
5
Welding process button
MMA welding
TIG welding
6
“Arcforce” button (welding characteristics) according to electrode type
7
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
8
Welding parameter setting rotary transducer
Setting of welding current and other welding parameter and their values
9
VRD
VRD open circuit voltage reduction (VRD machine version)