Design and function
Special parameters (advanced settings)
299-031000-TWD01
18.10.2016
59
5.7.1
Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off machine at the main switch.
• Press and hold the "left parameter selection" button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary dial.
• Set or change the parameters by turning the "arc length correction/select welding program"
rotary dial.
EXIT (Exit the menu)
• Press the "right parameter selection" button (switch machine off and on again).
ENTER
B
A
A
l
0
l
0
+
EXIT
B
NAVIGATION
A
B
A
Figure 5-38
Display
Setting/selection
Ramp time for wire inching
0 = -------- normal inching (10s ramp time)
1 = -------- fast inching (3s ramp time) (Ex works)
Lat. and sp. lat. tapping start
0 = -------- no latched tapping start (Ex works)
1 = -------- latched tapping start possible