Design and function
MIG/MAG welding
299-031000-TWD01
18.10.2016
45
5.3.8
Conventional MIG/MAG Welding (GMAW non synergic)
You can only change the JOB number when no welding current is flowing.
2
3s
1
3
Figure 5-23
Item Symbol
Description
0
1
JOB-
LIST
Welding task push-button (JOB)
Select the welding task from the welding task list (JOB-LIST). The list can be found
inside the protective cap on the wire feeder and in the appendix to these operating
instructions.
2
Welding parameter setting dial
For setting the welding performance, for selecting the JOB (welding task) and for
setting other welding parameters.
3
Select operating mode button
--------- Non-latched
-------- Latched
Automatic display mode switching:
If the wire speed or the voltage is changed, the display will switch briefly to show the respective
parameter. This means that you don't have to change the display mode before setting the
parameter.
If the display mode is set to display the welding current, it will always show "0" before welding
begins. Actual values are shown during welding; these can be changed as necessary using the
"welding parameter setting" rotary dial.