Teac TD-700T Instructions For Use Manual Download Page 6

6

Safety information

DISCLAIMER

TEAC disclaims all warranty, either expressed or implied, 
with respect to this product and the accompanying written 
materials. In no event shall TEAC be liable for any damages 
whatsoever (including, without limitation, damages for loss of 
business profits, business interruption, loss of business infor-
mation or other loss) arising out of the use of or inability to use 
this product.

Disposing of this product

When disposing of this product, including accessories, con-
sumable parts and related items, follow the regulations of the 
local, regional and national governments.

For European Customers

Disposal of electrical and electronic equipment and 
batteries and/or accumulators

a)  All electrical/electronic equipment and waste batteries/

accumulators should be disposed of separately from the 
municipal waste stream via collection facilities desig-
nated by the government or local authorities.

b)  By disposing of electrical/electronic equipment and 

waste batteries/accumulators correctly, you will help 
save valuable resources and prevent any potential nega-
tive effects on human health and the environment.

c)  Improper disposal of waste electrical/electronic equip-

ment and batteries/accumulators can have serious 
effects on the environment and human health because 
of the presence of hazardous substances in the 
equipment.

d)  The Waste Electrical and Electronic Equipment 

(WEEE) symbols, which show wheeled bins 
that have been crossed out, indicate that elec-
trical/electronic equipment and batteries/
accumulators must be collected and disposed 
of separately from household waste.
If a battery or accumulator contains more 
than the specified values of lead (Pb), mer-
cury (Hg), and/or cadmium (Cd) as defined 
in the Battery Directive (2006/66/EC, 
2013/56/EU), then the chemical symbols 
for those elements will be indicated beneath the WEEE 
symbol.

e)  Return and collection systems are available to end users. 

For more detailed information about the disposal of old 
electrical/electronic equipment and waste batteries/
accumulators, please contact your city office, waste 
disposal service or the shop where you purchased the 
equipment.

Pb, Hg, Cd

Summary of Contents for TD-700T

Page 1: ...Digital Transducer Indicator Instructions for Use Z TD 700T D01235291C...

Page 2: ...ording to designated values is a standard feature o o Product is RoHS compliant o o Optionally supports CC Link and RS 485 interfaces for easy connection with production lines and other systems o o Wa...

Page 3: ...e power cord as there is the danger of fire or electrical shock Never attempt to disassemble the product Carefully check connections and wiring before applying power Be sure to ground the product with...

Page 4: ...not install in the following environments o o Locations subject to temperatures exceeding the specified temperature and humidity ranges o o Locations with high salt or iron content o o Locations subje...

Page 5: ...y Canada s Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada Model for Europe DECLARATIO...

Page 6: ...ste batteries accumulators correctly you will help save valuable resources and prevent any potential nega tive effects on human health and the environment c Improper disposal of waste electrical elect...

Page 7: ...tion 30 4 9 3 Condition Setting 31 4 9 4 Comparison Setting 31 4 9 5 Hold Function Setting 31 4 9 6 System Settings 31 4 9 7 TEDS Settings 31 4 10 Setting value list 32 4 10 1 Calibration 32 4 10 2 Co...

Page 8: ...s 77 9 8 Reset to the Factory Settings 77 10 TEDS Settings 78 10 1 TEDS Data Change 78 10 2 Restore TEDS Data 79 10 3 TEDS Data 80 11 CC Link Settings 81 11 1 CC Link overview 81 11 2 Connections 81 1...

Page 9: ...12 14 1 Polling 0001 106 12 14 2 Status polling 0002 107 12 14 3 Indicator value polling 0003 108 12 14 4 Setting value writing execution command format 108 12 14 5 Setting value loading command form...

Page 10: ...10...

Page 11: ...n Press when changing a setting value to confirm the set ting item or setting value and move to the next item C ZERO ESC button When Cal Value Lock is OFF press and hold to use the Zero Balancing func...

Page 12: ...26 for information about compatible plugs DC IN 12V o o An AC adapter is included with the TD 700T for Japan and North America No adapter is included for other regions The included AC adapter conforms...

Page 13: ...the Calibration menu page If Remote Sense disabled TEDS enabled is selected calibration will occur automatically if a sensor with TEDS built in is connected o o The wire colors are those that we use i...

Page 14: ...on page 73 17 SEL2 18 COM This is the control input signal com mon terminal o o The control input signal is isolated from the unit s circuits by a photocoupler o o Signals are input to each terminal b...

Page 15: ...ay IndicatorValue Only Display Waveform display Function Menu Hold ON OFF Actual Load Calibration TEDS calibration Equivalent Input Calibration Static Strain Disp Mode Cal Value Lock Digital Zero Zero...

Page 16: ...change screen views NOTE The Home Screen will open about 15 seconds after power is supplied to the unit 1 8 1 Standard When high high limit and low low limit are enabled a b c d e f g h i When high h...

Page 17: ...tput and the Hysteresis setting is 0 f Indicator value 1 Names and functions of parts g High limit low limit high high limit and low low limit setting values Each setting value is shown If high high l...

Page 18: ...s active f q k r r m o p k High limit setting This shows the high limit value o o The high high limit is not shown l High limit value line This line corresponds to the high limit value The area higher...

Page 19: ...value 1 8 4 1 Vertical axis These values range from 0 to the maximum display page 43 1 8 4 2 Horizontal axis Each time you press the b button it changes as follows 10sec 30sec 100sec 1 8 4 3 Pausing t...

Page 20: ...1 0 45 1 0 o o The recommended panel thickness is 0 8 5 mm 2 Remove the left and right panel attachment fixtures While pulling their movable clasps away from the unit slide each one off the back of t...

Reviews: