4
−
1. AM TRACKING VOLTAGE ADJUSTMENTS
DC VOLTMETER ........................... CONNECT TO TEST POINT P5 and GND
NO.
Band
Frequency
Adjust for
Adjustment
1
AM
530KHz
2.2V
T1
2
AM
1720KHz
9.5V
TVC1
2. AM RF ADJUSTMENT
Signal Generator ........................ Connects to the AM ANT. Coil through the loop antenna.
Adjust for the indication of VTVM of the wave form of scope to be maximum.
BAND
Step
Frequency
Adjust for
Adjustment
1
630KHz
Maximum sensitivity
L2, T2
2
1420KHz
Maximum sensitivity
TVC2
3
Repeat steps 1 and 2 several times.
AM
NO.
Frequency
Adjust for
Adjustment
1
97.8MHz
L rejection
T4
2
P5
GND
3
97.8MHz
97.8MHz
TVR3
T5
L, R rejection
R rejection