TASCAM MD-CD1 RS-232C Protocol Specification
38
TEAC
Corporation
POWER ON STATUS
This command indicates that the controlled device has been powered-on.
Command F4
Machine ID
0
Data none
Request/Preset none
CHANGED STATUS
This command indicates that the operation or mode of the controlled device has changed.
Command F6
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Changed
Mechanical
Status
The status of the mechanism has changed
0 3
Changed
Track/EOM
Status
The track number has changed. The EOM
display/non-display state has changed.
Request/Preset none