background image

408-35037 

Rev 

A

 

of 5

 

3.4.

 

Dual-Carrier Terminals 

Terminal consisting of a contact body, crimp barrels, a tab and carrier strip adjacent to the crimp barrels of 
the contact, and, a tab and carrier strip adjacent to the contact body portion of the contact. 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 6 

4.

 

ADJUSTMENT PROCEDURE 

[FIGURE 7] 

NOTE 

The adjustment procedure is performed most easily with a small strip of terminals - approximately 4 to 5. 

1.  Loosen the Vertical and Horizontal Adjustment Screws just enough to allow the Vertical Adjustment 

Plate and Horizontal Adjustment Block to move. 

2.  Move the Vertical Adjustment Plate and Horizontal Adjustment Block so the terminal strip can be 

inserted into the Strip Guide; positioning the contact barrel against the Strip Guide surface indicated 
(see Figure 7). 

3.  Lower the Vertical Adjustment Plate into the transition area between the Insulation Barrel and the 

Wire Barrel of the terminal. 

NOTE 

Some terminals do not have an Insulation Barrel 

 in that case, use the transition area between the Wire Barrel and the 

Contact Body to set up the tool (see Figure 7; Contact Details). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 7    

 

Wire Barrel 

Transition Area 

Contact Body 

Contact Body 

Wire Barrel 

Transition Area 

Insulation 
Barrel 

Vertical 
Adjustment 
Plate 

Locate Terminal Against 
Strip Guide Surface 

Horizontal 
Adjustment 
Block 

Contact Details 

Tab 

Crimp Barrels 

Contact Body 

Tab 

Carrier Strip 

This Style of Terminal 

CANNOT 

Be Used with the Cutter

 

Carrier Strip 