READ THIS FIRST! 

  

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Operating Manual for the Battery 

 

Powered Hydraulic Pump Kit 

 

2063680-1

05 JAN 12  Rev B

1. INTRODUCTION

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. DESCRIPTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3. OPERATING PRECAUTIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1. Precautions for the Rechargeable Pump  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2. Precautions for the Battery Cartridge and Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3. Precautions for the Battery Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4. Precautions for the Battery Cartridge Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4. OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1. Battery Charging Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2. Attaching the Battery Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3. Attaching the Hydraulic Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.4. Attaching the Remote Control Cord  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.5. Controlling the Pump (Figure 6)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.6. Guide to Crimping Capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5. MAINTENANCE AND INSPECTION

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5.1. Before Storing the Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2. Daily Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.3. Semi-Annual Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.4. Oil Leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . 9

6. REPAIR/REPLACEMENT

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

7. TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

8. REVISION SUMMARY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

SAFETY  PRECAUTIONS

Summary of Contents for Tyco 2063680-1

Page 1: ...ic Pump Kit 2063680 1 05 JAN 12 Rev B 1 INTRODUCTION 3 2 DESCRIPTION 4 3 OPERATING PRECAUTIONS 5 3 1 Precautions for the Rechargeable Pump 5 3 2 Precautions for the Battery Cartridge and Pump 5 3 3 Pr...

Page 2: ...ds into installed application equipment NEVER alter modify or misuse the application equipment TOOLING ASSISTANCE CENTER CALL TOLL FREE 1 800 722 1111 CONTINENTAL UNITED STATES AND PUERTO RICO ONLY Th...

Page 3: ...cartridges 1804113 1 a 3 8 Inch female screw type coupler 311471 1 and a metal storage box 1804115 1 The metal storage box is not shown in Figure 1 When reading this manual pay particular attention to...

Page 4: ...TERY CARTRIDGE 1804113 1 Standard Battery Type Sealed Nickel Cadmium Voltage 14 4Vdc Rated Current 2 0 Ah Charge Time 25 minutes Dimension 3 5 In Long X 2 7 In Wide X 5 3 In High Weight 1 6 pounds HIG...

Page 5: ...4 The pump is a precision device and should not be dropped or subjected to shocks or other abuse 3 3 Precautions for the Battery Cartridge 1 Do not short circuit the contacts or expose the cartridge t...

Page 6: ...T leave the battery in the charger to cool The charger will not recognize that the battery is already inserted and will fail to charge the battery 4 Consult the Tooling Assistance Center at 1 800 722...

Page 7: ...lication head to the opposite side of the hose if it s not already attached 4 4 Attaching the Remote Control Cord Attach the remote control cord to the pump Remove the cap from the receptacle at the p...

Page 8: ...e following steps after the piston has reached it s lowest position 1 Remove the battery cartridge 2 Disconnect the plug of the remote control cord NOTE i Be sure that the cord does not become pulled...

Page 9: ...Carefully remove the sealing tape PTFE tape from the screw 3 Wrap NEW sealing tape one and one half times around the screw head 4 Begin wrapping the sealing tape 1mm to 2mm from the edge of the threa...

Page 10: ...ng happens Defective electrical supply Defective circuit board Remote control connection wire is disconnected Check the electrical connection Consult Tooling Assistance for repair service The pressure...