1.

 

INTRODUCTION 

This instruction sheet covers application, inspection and maintenance procedures for Hydraulic Crimping Head 
PN 1752868-1 shown in Figure 1. 

The crimping head accepts interchangeable die sets for a variety of terminals and splices for large wire sizes -
12 through 350 MCM range.  Refer to the instructions packaged with the specific die sets for compatible 
products, wire ranges, strip dimensions, and application procedures.   

This crimping head is designed for use with Foot Hydraulic Pump PN 1583659-1, Hand Hydraulic Pump PN 
1583661-1, or Electric Hydraulic Pumps; PN 1804700-1 (115 VAC) and PN 1804700-2 (220 VAC). 
 

Warning

: To avoid personal injury and potential damage to the crimp head, TE Connectivity (TE) requires the 

crimp head to operate at 9,800 to 10,200 PSI [676 to 703 bar].  TE recommends using 10,000 PSI [689 bar] TE 

Hydraulic Pumps as other manufacturers’ pumps may apply insufficient pressure (resulting in an inadequate 

crimp) or excessive pressure (resulting in failure of the head).  Additionally, the TE pump must be used to 
maintain CE certification; if 

using other manufacturers’ pumps

, the user is responsible for self-certification. 

 
Read these instructions, and all applicable references before inserting any die set assemblies and crimping any 
terminals or splices. 
 

NOTE 

Dimensions in this instruction sheet are in millimeters [with inches in brackets]. Illustrations and figures are for reference only 
and are not drawn to scale.

 

 
Reasons for reissue of this Instruction Sheet are provided in Section 9; REVISION SUMMARY    

Hydraulic Crimping 
Head, PN 1752868-1 

O

R

IG

IN

A

L

  IN

S

TR

U

C

TIONS

 

Summary of Contents for SOLISTRAND 1752868-1

Page 1: ...or use with Foot Hydraulic Pump PN 1583659 1 Hand Hydraulic Pump PN 1583661 1 or Electric Hydraulic Pumps PN 1804700 1 115 VAC and PN 1804700 2 220 VAC Warning To avoid personal injury and potential damage to the crimp head TE Connectivity TE requires the crimp head to operate at 9 800 to 10 200 PSI 676 to 703 bar TE recommends using 10 000 PSI 689 bar TE Hydraulic Pumps as other manufacturers pum...

Page 2: ...ned NOTE If crimping head must be removed after being in production pressure must be released in the hydraulic system before head is removed If using Electric Hydraulic Power Unit 1804700 1 or 2 disconnect power unit from power supply When using Hydraulic Foot Pump PN 1583659 1 or Hydraulic Hand Pump PN 1583661 1 depress the pressure release pedal to release pressure 4 DIE INSTALLATION AND REMOVAL...

Page 3: ...hold terminal or splice in place 3 Insert the stripped wire into the terminal or splice 4 Activate the power unit to complete the crimp 6 INSPECTION AND MAINTENANCE DANGER Verify hydraulic pressure is released and power supply is disconnected before following inspection and maintenance procedures unless otherwise specified in the procedure Each crimping head is assembled and inspected before shipm...

Page 4: ... Additionally inspect and service the head every month or 1 000 cycles Figure 3 Cleaning 1 Remove accumulations of dirt and grease on the crimping head especially in areas where dies are installed and product is crimped 2 Clean the entire head frequently with a clean lint free cloth Crimping Head Check Out Procedure If the ram fails to retract after completion of a crimping cycle the cause may be ...

Page 5: ... entire tool for evaluation and repair with a written description of the problem to CUSTOMER SERVICE 38 35 TE CONNECTIVITY CORPORATION P O BOX 3608 HARRISBURG PA 17105 3608 Tools may also be returned for evaluation and repair For tool repair service contact a TE representative at 1 800 526 5136 Item Number Part Number Description Quantity Per Head 1 21013 4 Screw Socket Head Self Locking 1 4 20 UN...

Page 6: ...s applied with a wrench Quick Disconnect Coupling The coupling mates hard or will not mate or release or it leaks oil or it sticks at the hose connection Replace coupling Ram Inspect the ram in the Power ON ram advanced position for evidence of galling cracks or oil leaks between the ram and the cylinder If there are cracks or leaks return the tool for repair see Section 7 If there is galling remo...