114-1016
5
of 8
Rev
EE
I. Locking Lance(s)
The locking lance(s) shall be set to within limits given in Figure 3.
3.4. PC Board
The pc board thickness shall be 0.157±0.18 [.062±.007]. The pc board hole size for the contact should be within
the tolerances specified in Figure 4.
Miniature
AMP-IN
350566
22-20
1.83±0.08 [.072±.003]
18
1.96±0.08 [.077±.003]
640108
26-22
1.40±0.10 [.055±.004]
640311
22-20
1.83±0.08 [.072±.003]
18
1.96±0.08 [.077±.003]
640401
26-22
1.40±0.10 [.055±.004]
640663
26-22
1.40±0.10 [.055±.004]
770060
18-14
3.18±0.08 [.125±.003]
770565
22-20
1.83±0.08 [.072±.003]
18
1.96±0.08 [.077±.003]
794013
12
3.18±0.08 [.125±.003]
794037
12
3.18±0.08 [.125±.003]
10
3.76±0.08 [.148±.003]
Miniature
AMP-IN 2000
794121
22-20
1.83±0.08 [.072±.003]
18
1.96±0.08 [.077±.003]
794122
26-22
1.40±0.10 [.055±.004]
Figure 4
3.5. Inserting Contact into PC Board Hole
The contact must be inserted into the pc board hole until the locking lance(s) are through the pc board hole.
For the miniature AMP-IN 2000contact, the insulation stop/positive board stop will prevent the contact from
being further inserted in the hole. See Figure 5.
Miniature AMP-IN Contact
Miniature AMP-IN 2000 Contact
Locking Lances Through
PC Board Hole
Locking Lance Through
PC Board Hole
Insulation Stop/
Positive Board Stop
Against PC Board (Ref)
Figure 5
CONTACT
WIRE SIZE (AWG)
PC BOARD HOLE SIZE
TYPE
BASE PART NUMBER