background image

114-1016

5

 of 8

Rev 

EE

I. Locking Lance(s)

The locking lance(s) shall be set to within limits given in Figure 3.

3.4. PC Board

The pc board thickness shall be 0.157±0.18 [.062±.007]. The pc board hole size for the contact should be within 
the tolerances specified in Figure 4.

Miniature 

AMP-IN

350566

22-20

1.83±0.08 [.072±.003]

18

1.96±0.08 [.077±.003]

640108

26-22

1.40±0.10 [.055±.004]

640311

22-20

1.83±0.08 [.072±.003]

18

1.96±0.08 [.077±.003]

640401

26-22

1.40±0.10 [.055±.004]

640663

26-22

1.40±0.10 [.055±.004]

770060

18-14

3.18±0.08 [.125±.003]

770565

22-20

1.83±0.08 [.072±.003]

18

1.96±0.08 [.077±.003]

794013

12

3.18±0.08 [.125±.003]

794037

12

3.18±0.08 [.125±.003]

10

3.76±0.08 [.148±.003]

Miniature

 AMP-IN 2000

794121

22-20

1.83±0.08 [.072±.003]

18

1.96±0.08 [.077±.003]

794122

26-22

1.40±0.10 [.055±.004]

Figure 4

3.5. Inserting Contact into PC Board Hole

The contact must be inserted into the pc board hole until the locking lance(s) are through the pc board hole. 

 

For the miniature AMP-IN 2000contact, the insulation stop/positive board stop will prevent the contact from 
being further inserted in the hole. See Figure 5.

Miniature AMP-IN Contact

Miniature AMP-IN 2000 Contact

Locking Lances Through 

PC Board Hole

Locking Lance Through 

PC Board Hole

Insulation Stop/

 

Positive Board Stop 

 

Against PC Board (Ref)

Figure 5

CONTACT

WIRE SIZE (AWG)

PC BOARD HOLE SIZE

TYPE

BASE PART NUMBER

Summary of Contents for Miniature AMP-IN

Page 1: ...uring the soldering process and the insulation stop positive board stop prevents the wire insulation from being inserted and the contact from being over inserted into the pc board hole These requireme...

Page 2: ...lection and Preparation The contacts accept stranded wire sizes 26 to 10 AWG with an insulation diameter range given in Figure 2 Wire strip length shall be as given in Figure 2 CAUTION Care shall be t...

Page 3: ...ar Bellmouth 0 38 015 Max End of Wire Conductor to Wire Barrel X X Miniature AMP IN 2000 Contact X X See Detail A See Detail A Wire Insulation Not Crimped in Stabilizer Barrel Wire Conductors and Insu...

Page 4: ...034 114 1016 4 of 8 Rev EE Figure 3 End F Cutoff Tab and Burr The carrier strip cutoff tab and burr must be no more than the dimensions given in Figure 3 G Rear Bellmouth The rear bellmouth length mus...

Page 5: ...7 003 794013 12 3 18 0 08 125 003 794037 12 3 18 0 08 125 003 10 3 76 0 08 148 003 Miniature AMP IN 2000 794121 22 20 1 83 0 08 072 003 18 1 96 0 08 077 003 794122 26 22 1 40 0 10 055 004 Figure 4 3 5...

Page 6: ...opyl Alcohol Solvent 5 100 C 212 F KESTER 5778 Aqueous KESTER 5779 Aqueous LONCOTERGE 520 Aqueous LONCOTERGE 530 Aqueous Terpene Solvent C Cleaning After soldering removal of fluxes residues and activ...

Page 7: ...onitor CQM Applicators for Side Feed and End Feed Applications See Table 408 9640 AMP O LECTRIC Model G Terminating Machines 354500 409 5842 Miniature AMP IN 26 22 1 02 1 78 040 070 466739 1 466739 4...

Page 8: ...THROUGH PC BOARD HOLE LOCKING LANCE MUST BE COMPLETELY THROUGH PC BOARD HOLE WIRE INSULATION SHOULD NOT BE CRIMPED IN STABILIZER BARREL INSULATION STOP POSITIVE BOARD STOP MUST NOT BE TERMINATED THERE...

Reviews: