3.
WIRES
The following designations are used in this specification. The illustrations are exemplary and schematically.
Assessment of the wires
To ensure the required electrical crimp contactability with stable crimp resistance a permissible maximum storage
period of 8 months for unprocessed cable (referring to cable manufacturer production date) must be respected.
Wire selection
The contact system is released for the application with wires specified in
Chapter 3.4
The released contact-wire-combinations and crimp parameters are given in
Other wires require the validation approval of the TE engineering department.
The wires are applied as single wire terminations. Double terminations are not intended.
Wire preparation
The cable insulation must be stripped before crimping. The stripping length of the outer insulation and shield are
defined in the assembly instructions in
Chapter 6
The insulation must be cut accurately and pulled off from the conductor. Offcut of insulation may not remain on
the conductor. Single strands may not be damaged, fanned out, cut or pulled out. Furthermore, the operator
should avoid touching the bare single strands and the strands shall not be twisted. All single strands need to be
caught in the crimp and not a single strand must remain outside the crimp.
Cable Specifications of prescribed Cables
AC-cable: Cross-section
5 x 6,0mm²
Supplier
:
Coroplast
Outer Diameter
:
16,3
-0,6
mm
Cable description
:
FHLR2GCB2G 5x6.0mm² acc. LV216-2 table A5
Supplier Part No.:
9-2641 (5x6,0mm²)
PE-cable: Cross-section
16mm²
Supplier
:
Leoni
Outer Diameter
6,9
-0,2
mm
Cable description
:
FLRYW 16,0 / 6,8 / 0,41 acc. ISO 6722
– Class C
Supplier Part No.:
76B00436# (colour code Green/Yellow)
Signal-cable: Cross-section 12 x 0,35mm²
Supplier:
TE
Outer Diameter:
7,1
-0,4
mm
Cable description:
ASC120875A