TE Connectivity D-150-Z Series Installation Procedures Manual Download Page 4

 

Installation Procedure for Cable Splice shield Kits for RG-Cables 

RPIP-1108 
Revision A 
April, 2016 

Devices Installation Procedure 

 

 
© 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information. 
 
TUS-24-4006 rev E, 2 Aug 12 

If this document is printed, it becomes uncontrolled. Check for latest revision. 

Page 4 of 6 

 

 

g. 

Perform steps a thru d above to the right end of the cable to be spliced.  

 

h. 

Insert exposed center conductor into the crimp barrel. Ensure it is fully 
inserted and flush with the cable dielectric. Trim excess conductor as 
needed.  

 

i. 

Crimp the center and then the right side of the crimp barrel so that it has a 
continuous, hexagonal appearance. 

 

 

 

j. 

Insert the dielectric insert over the crimp barrel. If needed, trim the 
minimum amount form the length of the insert for a snug fit. Limiting air 
gaps improves splice performance. 

 

 

 

k. 

Apply pressure on the two halves of the dielectric insert and apply one 
revolution and one quarter of PTFE tape P-422 (A-A-59474, Type 1, Class 
4) over the insert to hold in place. Smooth out edges to remove any air 
voids. 