Installation Procedure for Cable Splice shield Kits for RG-Cables
RPIP-1108
Revision A
April, 2016
Devices Installation Procedure
© 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information.
TUS-24-4006 rev E, 2 Aug 12
If this document is printed, it becomes uncontrolled. Check for latest revision.
Page 4 of 6
g.
Perform steps a thru d above to the right end of the cable to be spliced.
h.
Insert exposed center conductor into the crimp barrel. Ensure it is fully
inserted and flush with the cable dielectric. Trim excess conductor as
needed.
i.
Crimp the center and then the right side of the crimp barrel so that it has a
continuous, hexagonal appearance.
j.
Insert the dielectric insert over the crimp barrel. If needed, trim the
minimum amount form the length of the insert for a snug fit. Limiting air
gaps improves splice performance.
k.
Apply pressure on the two halves of the dielectric insert and apply one
revolution and one quarter of PTFE tape P-422 (A-A-59474, Type 1, Class
4) over the insert to hold in place. Smooth out edges to remove any air
voids.